Telephone Cables 
CW 1128 Outdoor Telephone Cables CW 1198 Armoured Outdoor Telephone Cables CW1308 Indoor Telephone Cables VDE Standard Indoor Telephone Cables  

CW1308 Unarmoured Indoor Telephone Cable

Reference Standard: CW1308

Application:

This cable is used for communication and telephone systems where are installed indoor; Also it's designed to be

terminated in Insulation Displacement Connectors (IDC).

Conductor Material: Solid annealed copper referred to BS6360

Insulation Material: PVC

Laying-up: Pairs; Triples; Units

Drain Wire: Solid annealed copper

Wrapping: Polyester Tape

Filler: Petrolatum Jelly filled

Sheath Material: PVC

Sheath Color: Black

Shape: Circular in cross-section

Voltage Rating: 300/500V

Temperature Rating: 0 ℃ to 70 ℃

Bending Radius: 8 x overall diameter

Electrical Performance:

Conductor Diameter (mm) Insulation Resistance of per km at 20 o C Max. (Ohms) Capacitance Unbalance of per km
Max. (pF)
0.40 153.0 200
0.50 97.8 500
1.38 12.4 N/A

CW1308 Unarmoured Indoor Telephone Cable (Pairs)

Number of Pairs Conductor Diameter (mm) Nominal Thickness of Insulation (mm) Nominal Thickness of Sheath (mm) Nominal Overall Diameter (mm) Nominal Weight (kg/km)
2 1/0.4 0 0.15 0.4 3.9 .
3 1/0.40 0.15 0.5 5.3 .
4 1/0.40 0.15 0.5 5.8 .
6 1/0.40 0.15 0.6 6.8 .
10 1/0.40 0.15 0.6 8.3 .
12 1/0.40 0.15 0.7 8.9 .
20 1/0.40 0.15 0.7 10.4 .
25 1/0.40 0.15 0.8 11.1 .
2 1/0.50 0.15 0.65 5.0 .
3 1/0.50 0.15 0.65 5.8 28.0
4 1/0.50 0.15 0.6 6.8 35.5
6 1/0.50 0.15 0.6 8.3 43.0
10 1/0.50 0.15 0.7 9.1 64.0
12 1/0.50 0.15 0.7 9.8 .
20 1/0.50 0.15 0.8 10.7 123.0
25 1/0.50 0.15 0.8 11.4 150.0


CW1308 Unarmoured Indoor Telephone Cable (Triples)

Number of Triples Conductor Diameter (mm) Nominal Thickness of Insulation (mm) Primary Thickness of Sheath (mm) Secondary Thickness of Sheath (mm) Nominal Overall Diameter (mm)
1 1/0.40 0.15 0.4 - 3.8
5 1/0.40 0.15 0.4 0.8 13.0
1 1/0.50 0.15 0.4 - 4.0
5 1/0.50 0.15 0.4 0.8 13.5


CW1308 Unarmoured Indoor Telephone Cable (Units)

Conductor Diameter (mm) Nominal Thickness of Insulation (mm) No. of Pairs Size of Unit Nominal Thickness of Sheath (mm) Nominal Overall Diameter (mm)
1/0.40 0.15 8 1/2*16 0.6 7.2
1/0.40 0.15 16 16 0.7 9.8
1/0.40 0.15 32 16 0.8 12.0
1/0.40 0.15 64 16 1.1 16.0
1/0.40 0.15 30 30 0.8 11.8
1/0.40 0.15 120 30 1.6 24.8
1/0.40 0.15 150 30 1.7 26.0
1/0.50 0.15 8 1/2*16 0.6 7.6
1/0.50 0.15 16 16 0.7 10.2
1/0.50 0.15 32 16 0.8 12.4
1/0.50 0.15 64 16 1.1 16.5
1/0.50 0.15 128 16 1.6 25.4
1/0.50 0.15 256 16 2.0 35.2
1/0.50 0.15 10 1/2*20 0.6 8.6
1/0.50 0.15 20 20 0.7 12.0
1/0.50 0.15 40 20 0.9 15.0
1/0.50 0.15 50 20 1.0 17.0
1/0.50 0.15 80 20 1.2 22.5
1/0.50 0.15 100 20 1.5 27.0
1/0.50 0.15 160 20 1.7 30.3
1/0.50 0.15 320 20 2.2 39.5
1/0.50 0.15 30 30 0.8 12.2
1/0.50 0.15 120 30 1.6 25.1
1/0.50 0.15 150 30 1.7 26.0