Industrial Cables  
H03VV-F H05VV-F H07RN-F more

Industrial Cables Single Core Fixed Wiring Cable

H01N2-D/E to BS 638

Application and Description

H01N2-D/E to BS 638 cables are used as a connection between the welding generator, the hand-electrode and

the work piece, they are suitable for use in the automobile industry, ship building, transport and conveyor

systems, tool making machinery, welding robots etc. H01N2-D/E to BS 638 cables retain their high flexibility even

under influence of ozone, light, oxygen, protective gases, oil and petrol. Robust design of these cables makes

them resistant to low and high temperature, fire, ozone and radiation, oils, acids, fats and petrols. These cables

are also ideal for outside installation in dry, moist and wet areas.

Cable Construction

Extra fine bare copper strands

Stranding to BS 6360 Class 5/6, IEC 60228 Class 5/6

Synthetic or paper separator over core

Chlorosulphonated Polyethylene (C.S.P.), HOFR (Heat and Oil Resistant and Flame Retardant) to BS7655 , black/

orange

H01N2-D/E to BS 638

Technical Characteristics

Working voltage: 100/100 volts

Test voltage: 1000 volts

Minimum bending radius: 12.0xOverall diameter (H01N2-D)

10xOverall diameter (H01N2-E)

Flexing Temperature: -25º C to +80º C

Fixed Temperature: -40º C to +80º C

Flame retardant: IEC 60332.1CS

Cable Parameter

H01N2-D (standard flexibility)

AWG
(No of Strands/ Strand Diameter)
No. of Cores x Nominal Cross Sectional Area
#xmm²
Nominal
Thickness of Insulation mm
Nominal Overall Diameter mm Nominal Copper Weight kg/km Nominal Weight kg/km
8(320/32) 1x10 2.0 7.7-9.7 96 135
6(512/32) 1x16 2.0 8.8-11.0 154 205
4(800/32) 1x25 2.0 10.1-12.7 240 302
2(1120/32) 1x35 2.0 11.4-14.2 336 420
1(1600/32) 1x50 2.2 13.2-16.5 480 586
2/0(2240/32) 1x70 2.4 15.3-19.2 672 798
3/0(3024/32) 1x95 2.6 17.1-21.4 912 1015
4/0(614/24) 1x120 2.8 19.2-24 1152 1310
300MCM(765/24) 1x150 3.0 21.2-26.4 1440 1620
350MCM(944/24) 1x185 3.2 23.1-28.9 1776 1916
500MCM(1225/24) 1x240 3.4 25-29.5 2304 2540

H01N2-E(high flexibility)

AWG
(No of Strands/ Strand Diameter)
No. of Cores x Nominal Cross Sectional Area
#xmm²
Nominal
Thickness of Insulation mm
Nominal Overall Diameter mm Nominal Copper Weight kg/km Nominal Weight kg/km
8(566/35) 1x10 1.2 6.2-7.8 96 119
6(903/35) 1x16 1.2 7.3-9.1 154 181
4(1407/35) 1x25 1.2 8.6-10.8 240 270
2(1974/35) 1x35 1.2 9.8-12.3 336 363
1(2830/35) 1x50 1.5 11.9-14.8 480 528
2/0(3952/35) 1x70 1.8 13.6-17.0 672 716
3/0(5370/35) 1x95 1.8 15.6-19.5 912 1012
4/0(3819/32) 1x120 1.8 17.2-21.6 1152 1190
300MCM(4788/32) 1x150 1.8 18.8-23.5 1440 1305
500MCM(5852/32) 1x185 1.8 20.4-25.5 1776 1511