| Airport Cable | |||
Airport Cable
AIRPORT LV Cables
Backbone Coaxial Cables
RG 6/U
APPLICATION
RG 6/U Airprot cables are designed for CCTV, security, smoke detection and evacuation monitoring applications,
where continued functionality is required during a fire situation. Due to the zero halogen low smoke
construction, this cable is ideal for use in public, commercial and industrial environments.
CABLE CONSTRUCTION
Conductors: Copper clad steel
Insulation: Foam PE compound.
Screen 1: Aluminium foil
Screen 2: Aluminium wire braid
Outer Sheath: Thermoplastic PVC compound.
STANDARDS
Basic design to MIL-C-17

FIRE PERFORMANCE
| FlameRetardance (SingleVerticalWireTest)** | EN60332-1-2; IEC60332-1-2; BSEN 60332-1-2; VDE0482-332-1; NBN C30-004 (cat.F1);NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
|---|---|
| Reduced FirePropagation(Vertically-mountedbundledwires &cabletest)** | EN60332-3-24(cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBN C30-004 (cat.F2);NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note:
Asterisk * denotes superseded standard
Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
Physical AND THERMAL PROPERTIES
Temperature range during operation (fixed state): -30°C - +70°C
Temperature range during installation (mobile state): -5ºC - +60ºC
Minimum bending radius: 8 x Overall Diameter
Electrical Properties
Impedance:75±5Ω
Capacitance:54NF/kM
Velocityratio(%):82
Insulation resistance:>5000Mohm.km
Shield coverage:70%
DC resistance
Inner conductor:23.1Ω/km
Outer conductor:31 Ω/km
Attenuation
| Frequency(MHz) | Attenuation(dB/100m) | Attenuation(dB/100ft) |
|---|---|---|
| 50 | 5.0 | 1.5 |
| 100 | 6.4 | 1.96 |
| 200 | 9.2 | 2.8 |
| 500 | 14.5 | 4.4 |
| 600 | 15.9 | 4.9 |
| 800 | 17.7 | 5.4 |
| 1000 | 21.9 | 6.7 |
| 1350 | 24.9 | 7.6 |
| 1750 | 29.0 | 8.8 |
| 2050 | 33.1 | 10.1 |
| 2400 | 36.4 | 11.1 |
CONSTRUCTION PARAMETERS
| Cable Code | Conductor Diameter | Nominal Insulation Diameter | Nominal Screen No.xDiameter | Nominal Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|
| mm | mm | No. x mm | mm | kg/km | |
| RG6/U | 1.02 | 4.8 | 96*×0.12 | 7.0 | 43 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information