| Airport Cable | |||
300/500V PVC Insulated, PVC Sheathed Controlling Cables (1 Pair)
RE-YY (CU/PVC/PVC 300/500V Class 5)

APPLICATION
300/500V PVC Insulated, PVC Sheathed Controlling Cables (1 Pair) are used for: Intercom, Security, Sound,
Audio, Background Music, and Power Limited Control Circuits.
STANDARDS
Basic design adapted to BS 5308 and VDE 0812
FIRE PERFORMANCE
| FlameRetardance (SingleVerticalWireTest)** | EN60332-1-2; IEC60332-1-2; BSEN 60332-1-2; VDE0482-332-1; NBN C30-004 (cat.F1);NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
|---|---|
| Reduced FirePropagation(Vertically-mountedbundledwires &cabletest)** | EN60332-3-24(cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBN C30-004 (cat.F2);NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note:
Asterisk * denotes superseded standard
Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
VOLTAGE RATING
300/500V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to BS 6360 Class 5
Insulation: PVC insulation type TI1 to BS 7655
Outer Sheath: PVC sheath type T6 to BS 7655
COLOUR CODE
Insulation Color: Black , White
12AWG Jacket Color: Gray, Black
14AWG Jacket Color: Gray, Brown, Black, White
Electrical & Environmenta l Properties
Operating Temperature Range: -20˚C up to + 60˚C
12AWG Max.Capacitance Between Conductors @ 1 KHz: 109.55 pf/m Nom.
14AWG Max.Capacitance Between Conductors @ 1 KHz: 101.37 pf/m Nom.
Minimum Bending Radius: 6 x Overall Diameter
CONSTRUCTION PARAMETERS
| Conductor | Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight | Dc Resistanceper conductor @20℃ |
||
|---|---|---|---|---|---|---|---|
| NO.of PairsX Cross Section |
No./ Nominal Diameterof Strands |
Conductor Diameter |
|||||
| No.xAWG | No./mm | mm | mm | mm | mm | kg/km | Ω/km |
| 1x2x12 | 53/0.31 | 1.95 | 0.6 | 0.8 | 9.4 | 145 | 4.95 |
| 1x2x14 | 41/0.254 | 1.55 | 0.6 | 0.8 | 8.6 | 91 | 8.3 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information