|  | Airport Cable |  | |
|  | |||
|  |  | 
 LYAR
 LYAR    
      Applications
LYAR Airprot cables are used for connection between Control Tower and Constant Current Regulators (CCRs),
suitable for transmission of voice data up to 2,000 kHz.
Standards
NF C 32 070 C2
Construction

Conductor: Solid bare copper.
Insulation: PE.
Cable Element: Pairs.
Separator: One or more plastic tapes.
Shield: Polyester-aluminium tape with drain wire.
Inner Sheath: PVC.
Armour: Steel tapes.
Outer Sheath: PVC.
Technical Data
Rated Voltage Uo/U (Um) :200V
Maximum Conductor Temperature :90℃
Short Circuit Temperature :250℃
Operating Temperatures :-15℃~+70℃
Minimum Bending Radius :static: 10×OD; dynamic: 20×OD
Lead Free :Yes
Dimensions and Weight
| Construction | AWG | Nominal Overall Diameter | Nominal Weight | 
|---|---|---|---|
| No. ×mm² | - | mm | kg/km | 
| 5×2×0.20 | 24 | 9.9 | 147 | 
| 10×2×0.20 | 24 | 10.7 | 178 | 
| 15×2×0.20 | 24 | 11.7 | 222 | 
| 30×2×0.20 | 24 | 14.4 | 342 | 
| 56×2×0.20 | 24 | 18.1 | 537 | 
| 2×2×0.50 | 20 | 10.4 | 57 | 
| 3×2×0.50 | 20 | 10.6 | 70 | 
| 5×2×0.50 | 20 | 12.0 | 97 | 
| 10×2×0.50 | 20 | 14.6 | 174 | 
| 15×2×0.50 | 20 | 16.0 | 236 | 
| 30×2×0.50 | 20 | 24.4 | 441 | 
| 56×2×0.50 | 20 | 23.4 | 799 | 