Applications

FLYCY Airport cables are used as airfield lighting equipment primary cables for the series circuit connecting the

Constant Current Regulators and the isolating transformers, and between the isolating transformers.

Construction

Conductor: Solid or stranded bare copper conductor.

Insulation: PVC.

Optional Separator: Separator tape.

Shield: Concentric layer of bare copper wires, counter helix of a copper tape.

Sheath: PVC.

Standards

ENV 50213

IEC 60502-1

VDE 0271

FLYCY Airport cables

Technical Data

Rated Voltage Uo/U (Um) :1/2kV, 1.5/3kV, 2.5/5kV, 3/6kV, 5/10kV

Maximum Conductor Temperature :90℃

Short Circuit Temperature :250℃

Operating Temperatures :-40℃~+90℃

Minimum Bending Radius :15×OD

Flame Retardant :Yes

Impacted Resistant :Yes

Weather Resistant :Yes

Dimensions and Weight

1/2kV

Construction Nominal Insulation
Thickness
Nominal Shield
Cross Section
Nominal Sheath
Thickness
Nominal Overall
Diameter
Nominal Weight
No. ×mm² mm mm² mm mm kg/km
1×6 1.5 2.5 1.4 10.0 170

1.5/3kV

Construction Nominal Insulation
Thickness
Nominal Screen
Cross Section
Nominal Sheath
Thickness
Nominal Overall
Diameter
Nominal Weight
No. ×mm² mm mm² mm mm kg/km
1×6 2.8 2.5 1.4 12.5 240

2.5/5kV

Construction Nominal Insulation
Thickness
Nominal Shield
Cross Section
Nominal Sheath
Thickness
Nominal Overall
Diameter
Nominal Weight
No. ×mm² mm mm² mm mm kg/km
1×6 3.0 4 1.4 13.0 250

3/6kV

Construction Nominal Insulation
Thickness
Nominal Shield
Cross Section
Nominal Sheath
Thickness
Nominal Overall
Diameter
Nominal Weight
No. ×mm² mm mm² mm mm kg/km
1×6 3.0 4 1.4 13.0 250
1×16 3.0 6 1.4 15.0 465

5/10kV

Construction Nominal Insulation
Thickness
Nominal Screen
Cross Section
Nominal Sheath
Thickness
Nominal Overall
Diameter
Nominal Weight
No. ×mm² mm mm² mm mm kg/km
1×6 3.8 6 1.4 16.5 360
1×10 3.8 6 1.4 17.0 390