Medium Voltage High Temperature Resistant Cables +180°C
Application
Medium Voltage High Temperature Resistant Cables +180°C are specifically designed for applications
requiring for high temperature and oil resistant, suitable used for linking generators to transformers positioned
up in the nacelle.
Standards
IEC 60092
Construction

Conductor: Stranded tinned copper wires, class 5 according to IEC 60228.
Tape: Polyester tape (up 16 mm²), Semi-conductive layer (only for 6.6 and 13.8 kV).
Insulation: Silicone rubber insulation.
Braid: PUR varnished synthetic yarn braid.
Technical Data
Rated Voltage U0/U (Um):1.1kV-15kV
Operating Temperatures:-55℃~+180℃
Minimum Bending Radius:6×OD (1.1kV); 12×OD (>=1.1kV)
Flame Retardant:IEC 60332-1/IEC 60332-3
Halogen Free:IEC 60754
Corrosive Gases:IEC 60754
Smoke Density:IEC 61034
Oil Resistant:Yes
Ozone Resistant:Yes
UV Resistant:Yes
Cold Resistant:CSA C 22.2
Dimensions and Weight
1.1kV
| Construction | Nominal Overall Diameter | Nominal Weight |
|---|---|---|
| No. of cores×mm² | mm | kg/km |
| 1×2.5 | 4.5 | 36 |
| 1×4 | 5.0 | 52 |
| 1×6 | 5.4 | 69 |
| 1×10 | 6.4 | 111 |
| 1×16 | 8.6 | 177 |
| 1×25 | 10.3 | 267 |
| 1×35 | 11.6 | 365 |
| 1×50 | 13.6 | 510 |
| 1×70 | 15.7 | 701 |
| 1×95 | 17.9 | 926 |
| 1×120 | 19.8 | 1154 |
| 1×150 | 21.9 | 1432 |
| 1×185 | 24.3 | 1761 |
| 1×240 | 26.9 | 2284 |
3.3-4.2kV
| Construction | Nominal Overall Diameter | Nominal Weight |
|---|---|---|
| No. of cores×mm² | mm | kg/km |
| 1×2.5 | 6.3 | 54 |
| 1×6 | 7.3 | 90 |
| 1×10 | 8.2 | 135 |
| 1×16 | 10.4 | 208 |
| 1×25 | 12.0 | 302 |
| 1×35 | 13.2 | 401 |
| 1×50 | 15.4 | 559 |
| 1×70 | 17.5 | 775 |
| 1×95 | 19.5 | 981 |
| 1×120 | 21.4 | 1215 |
| 1×150 | 23.1 | 1481 |
| 1×185 | 25.1 | 1798 |
| 1×240 | 27.5 | 2314 |
6.6-7.2kV
| Construction | Nominal Overall Diameter | Nominal Weight |
|---|---|---|
| No. of cores×mm² | mm | kg/km |
| 1×4 | 7.6 | 81 |
| 1×6 | 8.0 | 99 |
| 1×10 | 9.0 | 145 |
| 1×16 | 11.3 | 225 |
| 1×25 | 12.9 | 322 |
| 1×35 | 14.1 | 423 |
| 1×50 | 16.3 | 584 |
| 1×70 | 18.3 | 785 |
| 1×95 | 20.2 | 1006 |
| 1×120 | 22.0 | 1238 |
| 1×150 | 24.1 | 1525 |
| 1×185 | 26.1 | 1844 |
| 1×240 | 28.3 | 2355 |
13.8-15.0kV
| Construction | Nominal Overall Diameter | Nominal Weight |
|---|---|---|
| No. of cores×mm² | mm | kg/km |
| 1×10 | 12.1 | 205 |
| 1×16 | 14.0 | 288 |
| 1×25 | 15.5 | 390 |
| 1×35 | 16.7 | 497 |
| 1×50 | 18.5 | 655 |
| 1×70 | 20.6 | 864 |
| 1×95 | 22.4 | 1093 |
| 1×120 | 24.2 | 1332 |
| 1×150 | 26.5 | 1637 |
| 1×185 | 28.5 | 1966 |
| 1×240 | 30.7 | 2486 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information