| Windmill Cables | |||
| EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable | HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable | Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ | more |
Windmill Cables
H05VVC4V5-K 300/500V
Application
H05VVC4V5-K 300/500V screened cables are used as supply or interconnecting cable for measuring,
controlling and regulating for light and medium mechanical stresses.
Standards
HD 21.13 S1
DIN VDE 0281 Part. 13/5/96
Construction

Conductor: Stranded bare copper, class 5/class 6 according to IEC 60228.
Insulation: PVC Type YI 4.
Inner Sheath: PVC.
Screen: Tinned copper braid.
Outer Sheath: PVC oil resistant Type YM 5.
Technical Data
| Rated Voltage Uo/U (Um) | 300/500 V |
|---|---|
| Operating Temperatures | flexing: -15℃~+80℃; fixed: -40℃~+80℃ |
| Minimum Bending Radius | flexing: 20×OD; fixed: 10×OD |
| Flame Retardant | IEC 60332-1 |
| Oil Resistant | Yes |
| Ozone Resistant | Yes |
| Silicone Free | Yes |
Dimensions and Weight
| Construction | Nominal Overall Diameter | Nominal Weight |
|---|---|---|
| No. of cores×mm² | mm | kg/km |
| 3G0.75 | 8.6 | 108 |
| 4G0.75 | 9.5 | 123 |
| 5G0.75 | 10.0 | 147 |
| 7G0.75 | 11.9 | 189 |
| 12G0.75 | 14.7 | 296 |
| 25G0.75 | 19.5 | 529 |
| 3G1 | 9.3 | 130 |
| 4G1 | 9.9 | 150 |
| 5G1 | 11.0 | 191 |
| 7G1 | 12.6 | 223 |
| 12G1 | 15.1 | 322 |
| 18G1 | 17.9 | 455 |
| 25G1 | 21.7 | 668 |
| 3G1.5 | 10.1 | 146 |
| 4G1.5 | 11.1 | 179 |
| 5G1.5 | 12.5 | 221 |
| 7G1.5 | 14.5 | 303 |
| 12G1.5 | 17.6 | 448 |
| 18G1.5 | 21.2 | 637 |
| 25G1.5 | 24.7 | 845 |
| 47G1.5 | 32.0 | 1480 |
| 3G2.5 | 11.6 | 207 |
| 4G2.5 | 12.9 | 247 |
| 5G2.5 | 14.4 | 309 |
G: with yellow/green earth core
×: without yellow/green earth core