TUNNEL CABLES |
||||||||||
TUNNEL CABLES
3GSEYQY
Application
3GSEYQY cables are used for the connection of mobile operating equipments. In mines and underground
excavations with hazardous environments, in stationary operation, e.g.highvoltage transformers in mining and
tunneling. It can be used also for powering main pannels and switchboards in tunneling applications.
CABLE CONSTRUCTION
conductor:Circular Stranded Plain Annealed Copper Conductor (class 2 acc. to IEC 60228)
Insulation:3Gl3 type EPR Compound
Electrical Field Control:Extruded inner and outer rubber semiconductive layer
Core Identification:Natural coloring with black semiconductive layer
Screen:Copper tapes applied over each main core
Lay Up:3-Screened Cores will be laid up in concentrically
Bedding:PVC filler
Armour:Galvanized Steel Wire Braid (CSWB) Min90%
Outer Sheath:5GM5 Type elastomer compound. Red
STANDARDS

| construction | DIN VDE 0250-605 & IEC 60502-2 |
|---|---|
General Requirements |
DIN VDE 0250-1 |
Guide Use |
DIN VDE 0298-3 |
Electrical Tests |
DIN VDE 0472-501, 503, 508 |
Non-Electrical Tests |
DIN VDE 0472-401. 402,602,303, 615 |
Under Fire Condition Tests |
DIN VDE 0472-803, 804 |
Flame Retardant |
VDE 0482-332-1-2,DIN EN 60332-1-2,IEC 60332-1 |
Technical Characteristics
| Rated Voltage | 18 / 30 KV |
|---|---|
AC Test Voltage |
48 KV |
Max.Permissible Operating Voltage AC |
20.8 / 36 KV |
Max.Permissible Operating Voltage DC |
27 / 54 KV |
Min Bending Radius Current Carrying |
Acc. to DIN VDE 0298 part 3 |
capacity |
According to DIN VDE0298, Part 4 |
Max. Short circuit Temperature |
250°C |
Max. conductor Temperature |
90°C |
Working Temperature |
|
Fixed |
-25°C - +80°C |
Mobile |
+5°C - +80°C |
Max.Tensile Load Of cable |
15N/mm² |
max.torsion |
25°/m |
Dimensions And Weight
| Cross Section (mm²) | Overall Diameter |
max.Dc |
Appro. Weight (kg/km) |
|---|---|---|---|
3x25/16 |
65.1-72.0 |
0.727 |
6860 |
3x35/16 |
68.0-75.1 |
0.524 |
7640 |
3x50/16 |
70.8-78.3 |
0.387 |
8520 |
3x70/16 |
74.5-82.4 |
0.268 |
9760 |
3x95/16 |
79.0-87.2 |
0.193 |
11280 |
3x120/16 |
82.2-90.9 |
0.153 |
12600 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information