Telephone Cables
Outdoor Telephone Cables Indoor Telephone Cables Indoor/Outdoor Telephone Cables Special Telephone Cables

Ordering Information

 PE Insulated Category 3 UTP/FTP Cables

Application

The cables are designed for medium frequency data or telephone systems, suitable for indoor or outdoor

insulations.

Standards

TIA/EIA-568B

IEC 61156-4

UL-444

ANSI/ICEA S-80-576

Construction

UTP/FTP Cables

UTP/FTP Cables

Conductors

Solid annealed bare copper sized 0.5mm (24 AWG) as per ASTM-B3/class 1 of IEC 60228

Insulation

Solid polyethylene as per ASTM D 1248/IEC 60708

Twisted Pairs

Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk

Cable Core Assembly

The 50-pair cable is composed of 4 units having 12 or 13 pairs each. All other cables are composed of 25-pair

units. Units are identified by colour coded binders

Core Wrapping

Non-hygroscopic dielectric tape fully enclosing the core with an overlap

Screen (optional)

An optional Aluminium/Polyester tape placed in contact with solid copper drain wire may be provided as an

option

Sheath

PVC or LSZH

Ripcord

Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Electrical Properties

Nominal Conductor Diameter mm 0.5
Maximum DC Resistance Ω/100m 9.38
Maximum Resistance Unbalance % 5
Maximum Capacitance Unbalance pair-to-ground @1KHz pF/100m 330
Minimum Worst Pair Structural Return Loss (SRL):    
       Up to 10 MHz dB 12
       Between 10 and 16 MHz dB 10
Impedance @1-16 MHz 85 - 115
Maximum Attenuation at 20°C    
       @64KHz dB/100m 0.9
       @256KHz dB/100m 1.3
       @512KHz dB/100m 1.8
       @772KHz dB/100m 2.2
       @1MHz dB/100m 2.6
       @4MHz dB/100m 5.6
       @8MHz dB/100m 8.5
       @10MHz dB/100m 9.7
       @16MHz dB/100m 13.1
Minimum Worst pair-to-pair NEXT Loss    
       @772KHz dB 43
       @1MHz dB 41
       @4MHz dB 32
       @8MHz dB 28
       @10MHz dB 26
       @16MHz dB 23
Minimum Relative Velocity of Propagation @10MHz dB 0.585

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 10 x Overall Diameter (unarmoured cable);15 x Overall Diameter (armoured cables)

Colour Code

Standard Colour Code is per TIA/EIA 568B or ICEA S-80-576 as given in Colour Code Chart.

Dimensions And Weight

PE INSULATED CATEGORY 3 UTP CABLES

Cable Code Number of Pairs Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
0.5mm Conductor, 0.9mm Insulated Wire, UTP, PVC Sheathed, Indoor
TP568-2YY-10P05-UTPC3 10 0.9 9.5 77
TP568-2YY-25P05-UTPC3 25 0.9 12.5 155
TP568-2YY-50P05-UTPC3 50 1.0 17.0 260
TP568-2YY-100P05-UTPC3 100 1.1 21.5 530
TP568-2YY-200P05-UTPC3 200 1.2 29.5 1100
TP568-2YY-300P05-UTPC3 300 1.3 33.5 1550
0.5mm Conductor, 0.9mm Insulated Wire, UTP, LSZH Sheathed, Indoor & Outdoor
TP568-2YH-10P05-UTPC3 10 0.9 10.0 80
TP568-2YH-25P05-UTPC3 25 0.9 14.0 150
TP568-2YH-50P05-UTPC3 50 1.1 16.5 280
TP568-2YH-100P05-UTPC3 100 1.4 21.5 530
TP568-2YH-200P05-UTPC3 200 1.7 30.0 900
TP568-2YH-300P05-UTPC3 300 1.7 36.0 1300
0.5mm Conductor, 0.9mm Insulated Wire, UTP, PE Sheathed, Outdoor
TP568-2Y2Y-10P05-UTPC3 10 0.9 9.5 80
TP568-2Y2Y-25P05-UTPC3 25 0.9 13.0 150
TP568-2Y2Y-50P05-UTPC3 50 1.0 16.0 280
TP568-2Y2Y-100P05-UTPC3 100 1.1 21.5 550
TP568-2Y2Y-200P05-UTPC3 200 1.2 28.5 1050
TP568-2Y2Y-300P05-UTPC3 300 1.3 34.5 1550

PE INSULATED CATEGORY 3 FTP CABLES

Cable Code Number of Pairs Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
0.5mm Conductor, 0.9mm Insulated Wire, FTP, PVC Sheathed, Indoor
TP568-2Y(St)Y-10P05-FTPC3 10 0.9 10.0 85
TP568-2Y(St)Y-25P05-FTPC3 25 0.9 13.5 170
TP568-2Y(St)Y-50P05-FTPC3 50 1.0 17.0 300
TP568-2Y(St)Y-100P05-FTPC3 100 1.1 22.0 570
TP568-2Y(St)Y-200P05-FTPC3 200 1.2 30.0 1120
TP568-2Y(St)Y-300P05-FTPC3 300 1.3 36.6 1630
0.5mm Conductor, 0.9mm Insulated Wire, FTP, LSZH Sheathed, Indoor& Outdoor
TP568-2Y(St)H-25P05-FTPC3 25 0.9 14.0 170
TP568-2Y(St)H-50P05-FTPC3 50 1.0 17.5 300
TP568-2Y(St)H-100P05-FTPC3 100 1.2 23.0 580
TP568-2Y(St)H-200P05-FTPC3 200 1.6 32.0 1120
TP568-2Y(St)H-300P05-FTPC3 300 1.6 35.0 1320
0.5mm Conductor, 0.9mm Insulated Wire, FTP, PE Sheathed, Outdoor
TP568-2Y(St)2Y-10P05-FTPC3 10 0.9 11.0 85
TP568-2Y(St)2Y-25P05-FTPC3 25 0.9 13.5 170
TP568-2Y(St)2Y-50P05-FTPC3 50 1.0 16.5 300
TP568-2Y(St)2Y-100P05-FTPC3 100 1.1 22.6 570
TP568-2Y(St)2Y-200P05-FTPC3 200 1.2 31.0 1070
TP568-2Y(St)2Y-300P05-FTPC3 300 1.3 35.5 1570