Telephone Cables
Outdoor Telephone Cables Indoor Telephone Cables Indoor/Outdoor Telephone Cables Special Telephone Cables

Ordering Information

 PE Insulated Air Core/Jelly Filled Paired Railway Signalling Cables (RF 0.3)

Application

The cables are designed to give good protection to the cable cores against inductive interference (RF=0.3). The

cables are used for outdoor signaling equipment.

Standards

RENFE E.T. 03.365.051.6

Construction

Telephone Cables

Telephone Cables

Conductors

Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228

Insulation

Solid polyethylene as per ASTM D 1248/IEC 60708

Twisted Pairs

Two insulated conductors are twisted into pairs with varying lays to minimize crosstalk

Cable Core Assembly

The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded

binders

Core Filling (optional)

The cable core interstices can be filled with petroleum jelly to avoid longitudinal water penetration inside the

cable

Core Wrapping

One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

Moisture Barrier (optional)

An optional copolymer coated aluminium tape of 0.2mm is applied longitudinally with an overlap

Bedding

PE or LSZH

Electrostatic Screen

Corrugated copper tape of 0.12mm is applied longitudinally with overlap

Electrostatic Armour

Two high permeability steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left

by the inner one

Sheath

PVC or LSZH

Ripcord

Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Electrical Properties

Nominal Conductor Diameter mm 0.9 1.4
Conductor Size mm2 0.636 1.539
Maximum Conductor Resistance @20°C Ω/km 28 12.1
Minimum Insulation Resistance @500V DC MΩ.km 35000 5000
Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km   0.3 0.3
                                      Induced Voltage Em 500V/Km   0.5 0.5
Maximum Resistance Unbalance % 2.5 2.5
Maximum Mutual Capacitance @0.8KHz nF/km 59 64
Maximum Capacitance Unbalance @1KHz pair-to-pair pF/500m 275 275
Maximum Capacitance Unbalance @1KHz pair-to-ground pF/500m 1200 1200
Maximum Average Attenuation @1KHz dB/km 0.7 0.46
Maximum Average Attenuation @10KHz dB/km 1.6 0.85
Maximum Average Attenuation @20KHz dB/km 2.1 1.3
Dielectric Strength Conductor to Conductor 1 min V DC 1500 1500
                          Conductor to Screen 1min   V DC 2000 2000
Dielectric Strength Conductor to Conductor 3secs  V DC 3000 3000
                          Conductor to Screen 3secs   V DC 4500 4500
Nominal Insulation Thickness mm 0.45 0.65
Nominal Insulated Conductor Diameter mm 1.8 2.7

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 15 x Overall Diameter

Colour Code

Position Number of pairs
1(Pilot) 2(Direct) 3 4 5
Centre BLACK NATURAL BLUE NATURAL YELLOW NATURAL RED NATURAL    
Layers BLACK NATURAL BLUE NATURAL YELLOW NATURAL RED NATURAL GREEN NATURAL

Dimensions And Weight

Cable Code Number of Pairs Nominal Bedding/ Sheath Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight kg/km
0.9mm Conductor, 1.8mm Insulated Wire
TP365-2Y2Y(CTS)2Y(DSTA)Y2P09-RF03 2 1.5/1.6 18.3 1300
TP365-2Y2Y(CTS)2Y(DSTA)Y6P09-RF03 6 1.5/1.6 21.7 1425
TP365-2Y2Y(CTS)2Y(DSTA)Y10P09-RF03 10 1.5/1.6 25.2 1650
TP365-2Y2Y(CTS)2Y(DSTA)Y14P09-RF03 14 1.5/1.6 26.7 1800
TP365-2Y2Y(CTS)2Y(DSTA)Y20P09-RF03 20 1.5/1.6 29.2 2275
TP365-2Y2Y(CTS)2Y(DSTA)Y28P09-RF03 28 1.6/1.8 32.3 2450
TP365-2Y2Y(CTS)2Y(DSTA)Y38P09-RF03 38 1.7/1.8 36.0 2895
TP365-2Y2Y(CTS)2Y(DSTA)Y54P09-RF03 54 1.7/1.8 40.5 3275
TP365-2Y2Y(CTS)2Y(DSTA)Y74P09-RF03 74 1.8/2.0 45.6 3775
TP365-2Y2Y(CTS)2Y(DSTA)Y96P09-RF03 96 1.9/2.0 49.8 4275
1.4mm Conductor, 2.7mm Insulated Wire
TP365-2Y2Y(CTS)2Y(DSTA)Y2P14-RF03 2 1.5/1.6 20.2 1615
TP365-2Y2Y(CTS)2Y(DSTA)Y6P14-RF03 6 1.5/1.6 25.7 1775
TP365-2Y2Y(CTS)2Y(DSTA)Y10P14-RF03 10 1.6/1.8 30.8 2200
TP365-2Y2Y(CTS)2Y(DSTA)Y14P14-RF03 14 1.6/1.8 32.8 2525
TP365-2Y2Y(CTS)2Y(DSTA)Y20P14-RF03 20 1.7/1.8 36.5 2975
TP365-2Y2Y(CTS)2Y(DSTA)Y28P14-RF03 28 1.7/1.8 40.5 3150
TP365-2Y2Y(CTS)2Y(DSTA)Y38P14-RF03 38 1.8/2.0 45.6 3695
TP365-2Y2Y(CTS)2Y(DSTA)Y58P14-RF03 58 2.0/2.2 52.3 3975
TP365-2Y2Y(CTS)2Y(DSTA)Y74P14-RF03 74 2.1/2.2 59.1 4475
TP365-2Y2Y(CTS)2Y(DSTA)Y96P14-RF03 96 2.2/2.3 66.0 4975