| JIS Shipboard Cables | |||
| 3.6/6KV, 6/10KV, 8.7/15KV | 0.6/1kV | 250V |
250V
[FA-] MPY-S, MPYC-S, MPYCY-S
STANDARDS
JISC 3410-1999
IEC 60332-1
IEC 60332-3 Cat.A(for FA-type)
CABLE CONSTRUCTION
![[FA-] MPY-S, MPYC-S, MPYCY-S [FA-] MPY-S, MPYC-S, MPYCY-S](MPY-S.jpg)
| Conductor | M | Tinned annealed stranded copper, class 2 according to IEC 60228 |
|---|---|---|
| Insulation | P | 85°C EPR as per JIS C 3401 |
| Individual shield | -S | Tinned copper wire braid |
| Cabling | Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used | |
| Bedding | Y | PVC as per JIS C 3401 |
| Armor | C | Galvanized steel wire braid |
| Sheath | Y | PVC as per JIS C 3401 |
| Core identification | Black No. on white insulation | |
| Outer sheath color | Black |
Cable Parameter
250V (FA-) MPY-S
| No. of cores |
Conductor | Thick. of insulation | Dia. of
shield wire |
Thick. of bedding | (FA-) MPY-S | ||||
|---|---|---|---|---|---|---|---|---|---|
| Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight | ||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.1 | 9.9 | 0.4 | 150 |
| 4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.2 | 11.6 | 0.5 | 230 |
| 7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.3 | 13.9 | 0.6 | 350 |
| 12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.4 | 18.2 | 0.8 | 570 |
| 19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.5 | 21.5 | 0.9 | 840 |
| 27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.7 | 26 | 1.1 | 1200 |
| 37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.8 | 29.2 | 1.2 | 1600 |
| 44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 2 | 33.2 | 1.4 | 2000 |
250V (FA-) MPYC-S
| No. of cores |
Conductor | Thick. of insulation | Dia. of
shield wire |
Thick. of bedding | Dia. of steel wire |
(FA-) MPYC-S | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
|||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.1 | 0.3 | 11.2 | 0.4 | 210 |
| 4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.2 | 0.3 | 12.9 | 0.5 | 300 |
| 7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.3 | 0.3 | 15.2 | 0.6 | 435 |
| 12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.4 | 0.3 | 19.5 | 0.8 | 685 |
| 19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.5 | 0.3 | 22.8 | 0.9 | 980 |
| 27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.7 | 0.3 | 27.3 | 1.1 | 1360 |
| 37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.8 | 0.3 | 30.5 | 1.2 | 1760 |
| 44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 2 | 0.4 | 35 | 1.4 | 2240 |
250V (FA-) MPYCY-S
| No. of cores |
Conductor | Thick. of insulation | Dia. of
shield wire |
Thick. of bedding |
Dia. of steel wire |
Thick. of covering |
(FA-) MPYCY-S | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
||||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.1 | 0.3 | 0.9 | 13.2 | 0.5 | 260 |
| 4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.2 | 0.3 | 0.9 | 14.9 | 0.6 | 360 |
| 7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.3 | 0.3 | 1 | 17.4 | 0.7 | 515 |
| 12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.4 | 0.3 | 1.1 | 21.9 | 0.9 | 795 |
| 19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.5 | 0.3 | 1.2 | 25.4 | 1 | 1120 |
| 27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.7 | 0.3 | 1.3 | 30.1 | 1.2 | 1540 |
| 37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.8 | 0.3 | 1.4 | 33.5 | 1.3 | 1970 |
| 44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 2 | 0.4 | 1.5 | 38.4 | 1.5 | 2500 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information