Rolling Stock Cables
EN 50264 EN 50306 EN 50382 Databus Cables NF F 63-826 NF F 63-808 NF F 63-827 RSE/STD/024 PART 6

 Rolling Stock Cables

RS 485 Databus Cables 300/500 V

FRL-MVB-02Y(ST)CH-IOS-xPyS/FRL-MVB-02YCH-OS-xPyS

Application

120 Ohm data transmission cables

Construction

Multipair Databus RS 485 Double Screened Cable

Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2).

Insulation: Cross linked foam PE or foam skin PE

Cable Element: Twisted pair

Pair Screen:Individual Aluminium tape

Overall Screen: Copper wire braid

Outer Sheath: Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Multipair Databus RS 485 Single Screened Cable

Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2)

Insulation: Cross linked foam PE or foam skin PE

Cable Element: Twisted pair

Overall Screen: Copper wire braid

Outer Sheath: Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Electrical Characteristic

Impedance:120 ohm ±15%

Capacitance:41nF/Km@1KHz

Insulation Resistance:5000 M ohm

Chemical & Environmental Properties

EN 60684-2: No fluorine

EN 50305; EN 60811-2-1: Resistance to mineral oil & fuel oil, acid & alkali

EN 50305 :Resistance to ozone

Fire Performance for Rolling Stock Application

EN 50306-2: Hazard levels HL1, HL2/HL3

DIN 5510-2: Protection level 1/2/3/4

BS 6853: Interior use 1a, 1b, II; Exterior use 1a, 1b, II

NF F 16-101: F0

EN45545-2: R15 Interior/ R16 Exterior HL1, HL2, HL3

FRL-MVB-02Y(ST)CH-IOS-xPyS 300/500 V

No.of Pairs Cross Sectional Area mm2

Number and Nominal Diameter of Strands

mm

Voltage Rating

V

Nominal Overall
Diameter

mm

Nominal Weight kg/km
1 0.22 7/0.2 300/500 4.5 58
2 0.22 7/0.2 300/500 6.2 79
4 0.22 7/0.2 300/500 6.5 118
1 0.5 16/0.2 300/500 6.6 79
2 0.5 16/0.2 300/500 9.0 105
4 0.5 16/0.2 300/500 9.8 145
1 0.75 24/0.2 300/500 9.5 115
2 0.75 24/0.2 300/500 10.3 135
4 0.75 24/0.2 300/500 11.6 182
1 1 30/0.2 300/500 11.5 125
2 1 30/0.2 300/500 12.5 150
4 1 30/0.2 300/500 13.5 180

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information

300/500V Multipair Databus RS 485 Single screened Cable

Cross- sectional Area :0.22mm2-1mm2

Voltage rating :300/500V

Conductor:Flexible Stranded Tinned Copper

Number of pair:1-4

Conductor class :IEC 60228 Class 5

Insulation:Cross linked Foam PE

Screen:Copper Wire Braid

Jacket:Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard:BS 6853 Category la,lb and 11 and NF F 16-101 FO

Electrical Characteristic

Impedance:120 ohm ±15%

Capacitance:41nF/Km@1KHz

Insulation Resistance:5000 M ohm

No. of Pairs Cross Sectional Area mm2

Number and Nominal Diameter of Strands

mm

Voltage Rating V

Nominal Overall
Diameter

mm

Nominal Weight kg/km
1 0.22 7/0.2 300/500 4.2 55
2 0.22 7/0.2 300/500 5.9 75
4 0.22 7/0.2 300/500 6.2 115
1 0.5 16/0.2 300/500 6.3 75
2 0.5 16/0.2 300/500 8.5 100
4 0.5 16/0.2 300/500 9.4 140
1 0.75 24/0.2 300/500 9.0 110
2 0.75 24/0.2 300/500 9.7 130
4 0.75 24/0.2 300/500 11.1 178
1 1 30/0.2 300/500 11.0 120
2 1 30/0.2 300/500 12.0 145
4 1 30/0.2 300/500 13.0 175

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information

300/500V Multipair Databus RS 485 Single screened Cable

Cross- sectional Area :0.22mm2-1mm2

Voltage rating :300/500V

Conductor:Flexible Stranded Tinned Copper

Number of pair:1-4

Conductor class :IEC 60228 Class 5

Insulation:Cross linked Foam PE

Screen:Copper Wire Braid

Jacket:Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Fire Standard:BS 6853 Category la,lb and 11 and NF F 16-101 FO

Electrical Characteristic

Impedance:120 ohm ±15%

Capacitance:41nF/Km@1KHz

Insulation Resistance:5000 M ohm


No. of Pairs Cross Sectional Area mm2 Number and Nominal Diameter of Strands
mm
Voltage Rating V

Nominal Overall
Diameter

mm

Nominal Weight kg/km
1 0.22 7/0.2 300/500 4.2 55
2 0.22 7/0.2 300/500 5.9 75
4 0.22 7/0.2 300/500 6.2 115
1 0.5 16/0.2 300/500 6.3 75
2 0.5 16/0.2 300/500 8.5 100
4 0.5 16/0.2 300/500 9.4 140
1 0.75 24/0.2 300/500 9.0 110
2 0.75 24/0.2 300/500 9.7 130
4 0.75 24/0.2 300/500 11.1 178
1 1 30/0.2 300/500 11.0 120
2 1 30/0.2 300/500 12.0 145
4 1 30/0.2 300/500 13.0 175

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information