| Railway Cables | ||||||||||
|
||||||||||
CCPSSP-FR0.3 n×2×0.9/1.4
Application
CCPSSP-FR0.3 n×2×0.9/1.4 cables are used as railway cables and can be installed directly into the ground or
in ducts.
Reference Standards
RENFE E.T. 03.365.051.6
Construction

Conductors: Soft annealed solid copper, 1.4 mm nominal diameter.
Insulation: PE insulation.
Cabling Element: Two insulated conductors are twisted together to form a pair.
Stranding: Pairs are helically stranded in concentric layers.
Core Wrapping: Two or more layers of plastic tape(s) with overlapping.
Screen: Copper tapes with overlap (protection against interference).
Inner Sheath: PE sheath.
Armour: Two layers steel tape (0.8mm thick).
Outer Sheath: PE sheath.
Electrical Characteristics at 20℃
| Nominal Conductor Diameter | mm | 0.9 | 1.4 |
|---|---|---|---|
| Maximum Conductor Resistance | Ω/km | 28.5 | 11.7 |
| Minimum Insulation Resistance @500 V DC | MΩ.km | 15000 | 15000 |
| Mutual Capacitance @1KHz | nF/km | 58 | 58 |
| Capacitance Unbalance @1KHz | |||
| Pair to Pair | pF/km | 260 | 260 |
| Pair to Earth | pF/km | 2625 | 2625 |
| Test Voltage @50Hz 1min | |||
| Core to Core | Veff | 2100 | 2100 |
| Core to Screen | Veff | 2500 | 2500 |
| Reduction Factor @100V/km 50Hz | 0.3 | 0.3 |
Mechanical and Thermal Properties
Minimum Bending Radius: 10×OD
Temperature Range: -40℃ to +60℃ (during operation);
-10℃ to +60℃ (during installation)
Dimensions And Weight
| Cable Code |
Number of |
Nominal Sheath Thickness |
Maximum Overall |
Nominal |
|
|---|---|---|---|---|---|
|
Inner |
Outer |
||||
| 0.9mm Conductor, 1.8mm Insulated Wire | |||||
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-6P0.9 |
6 | 1.5 | 1.6 | 19.2 | 720 |
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-10P0.9 |
10 | 1.5 | 1.6 | 24.0 | 1011 |
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-12P0.9 |
12 | 1.5 | 1.6 | 24.5 | 1067 |
| 1.4mm Conductor,2.7mm Insulated Wire | |||||
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-2P1.4 |
2 | 1.5 | 1.6 | 22.5 | 904 |
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-6P1.4 |
6 | 1.6 | 1.8 | 25.5 | 1155 |
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-7P1.4 |
7 | 1.6 | 1.8 | 26.9 | 1258 |
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-10P1.4 |
10 | 1.7 | 1.8 | 30.9 | 1542 |
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-11P1.4 |
11 | 1.7 | 1.8 | 30.9 | 1576 |
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-14P1.4 |
14 | 1.7 | 1.8 | 37.1 | 1827 |
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-20P1.4 |
20 | 1.8 | 2.0 | 37.9 | 2214 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information