RAILFEEDER Railway Power & Control Cables
Pigtail Rail Connection Cables to SE260L
Application
Pigtail Rail Connection Cables are designed for use in signalling equipment rooms.
Construction
Conductors: Stranded plain copper conductors to IEC 60228 class 2 or 5.
Insulation: FRPVC.
Outer sheath: FRPVC.
Optional:Limited fi re hazard pigtail rail connection cables: Stranded tinned copper conductors, LSZH composite insulation.
Reference Standards
SE260
UNE 21123

Electrical Characteristics at 20℃
| Nominal Conductor Cross Section | mm² | 0.6 |
|---|---|---|
| Maximum DC Conductor Resistance | Ω/km | 1.15/1.16* |
| Voltage Rating | KV | 0.6/1.0 |
*For LSZH cable
Mechanical and Thermal Properties
Minimum Bending Radius: 7.5×OD
Temperature Range:-25℃ to +85℃ (during operation);
-10℃ to +70℃ (during installation)
Dimensions And Weight
| Cable Code | No. of cores& Nominal
Conductor Cross Sectional Area No.×mm² |
No. & Nominal
Diameter of Strands No/mm |
Nominal
Insulation Thickness mm |
Nominal
Sheath Thickness mm |
Nominal
Overall Diameter mm |
Nominal Weight kg/km |
|---|---|---|---|---|---|---|
| RF260-VV-K-0.6/1KV-1G16 | 1×16 | 19/1.04 | 0.7 | 1.4 | 10.3 | 249 |
| RF260-RZ1-K-0.6/1KV-1G16 | 1×16 | 19/1.04 | 0.7 | 1.4 | 10.3 | 255 |
K is changed to U if the stranding class is changed from class 5 to class 2
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information