| Railway Cables | ||||||
|
||||||
FRA 316 SW4
Applications :
- FRA 316 SW4 cables are designed for flexible installations, inside and outside railway rolling stock.
Standards :
-
DIN 5510-2
Construction :


-
Inner conductor:Stranded silverplated copper.
- Crosslink Foam PE (SPEX).
-
Outer conductor(shield1):Silver plated copper.
-
Outer conductor(shield2):Silver plated copper.
-
Sheath:LSZH Elastomer.
Electrical Characteristics at 20 °C :
| Impedance | Ω | 50+/-2 |
|---|---|---|
| Nominal Capacitance Minimum Insulation Resistance | pF/m MΩ.km | 94.5 |
| 100000 | ||
| Inner Conductor Resistance | MΩ/km | 29.9 |
| Outer Conductor Resistance | MΩ/km | 7.5 |
| Attenuation |
||
| @10MHz | dB/100m | 7 |
| @50MHz | dB/100m | 17 |
| @100MHz | dB/100m | 24 |
| @150MHz | dB/100m | 30 |
| @200MHz | dB/100m | 35 |
| @300MHz | dB/100m | 44 |
| @400MHz | dB/100m | 52 |
| @450MHz | dB/100m | 56 |
| @500MHz | dB/100m | 59 |
| @600MHz | dB/100m | 66 |
| @800MHz | dB/100m | 78 |
| @850MHz | dB/100m | 81 |
| @900MHz | dB/100m | 83 |
| @950MHz | dB/100m | 86 |
| @1000MHz | dB/100m | 89 |
| @1800MHz | dB/100m | 127 |
| @1900MHz | dB/100m | 131 |
| @2000MHz | dB/100m | 135 |
|---|---|---|
| @2400MHz | dB/100m | 152 |
| @3000MHz | dB/100m | 175 |
| @4000MHz | dB/100m | 211 |
| @5000MHz | dB/100m | 245 |
| @6000MHz | dB/100m | 277 |
| Velocityofpropagation | % | 70.7 |
Mechanical and Thermal Properties :
-
Minimum Bending Radius:5mm (static)
-
Temperature Range:-40℃~+105℃
Dimensions and Weight :
| Conductor Construction No/mm | NominalInner Conductor Diameter mm | NominalOuter Conductor Diameter mm | NominalOverall Diameter mm | NominalWeight |
|---|---|---|---|---|
| 7/0.18 | 0.54 | 2.5 | 3.16 | 21 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information