Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

 Railway Cables

FIRERAIL Traction Cables For Railway Applications

300/500V Single Core Thin Wall Fire Resistant Traction Cables

 

 

Application

300/500V Single Core Thin Wall Fire Resistant Traction Cables designed for protected, fixed installation

inside and outside railway vehicles for connecting fi xed and moving parts.

Construction

Conductors: Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.

Flame Barrier : Mica tape.

Insulation: Electron beam crosslinkable thin wall LSZH compound.

Reference Standards

BS 6853 -1a

DIN 5510-1 1-4

NFF 16-101 F0

BS 6387

300/500V Single Core Thin Wall Fire Resistant Traction Cables

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 0.5 0.75 1.0 1.5 2.5
Maximum DC Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21
Voltage Rating KV 0.45/0.75

Mechanical and Thermal Properties

Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)

Temperature Range:-40℃ to +120℃

Dimensions And Weight

Cable Code No. of cores& Nominal Conductor Cross Sectional
Area
No.×mm²
Nominal Diameter of
Strands
No/mm
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
FRA-TW-0.5SU-FR-1C0.5S 1×0.5 16/0.20 0.30 2.0 8
FRA-TW-0.5SU-FR-1C0.75S 1×0.75 24/0.20 0.30 2.25 11
FRA-TW-0.5SU-FR-1C1S 1×1.0 32/0.2 0.35 2.50 14
FRA-TW-0.5SU-FR-1C1.5S 1×1.5* 30/0.25 0.35 2.8 19
FRA-TW-0.5SU-FR-1C2.5S 1×2.5* 50/0.25 0.35 3.2 29

*earth cable(coloured yellow/green)can be offered as an option.

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information