Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

 Railway Cables

FIRERAIL Traction Cables For Railway Applications

0.6/1KV Single Core Thin Wall Traction Cables

 

 

Application

0.6/1KV Single Core Thin Wall Traction Cables designed for protected, fixed installation inside and outside

railway vehicles for connecting fi xed and moving parts.

Construction

Conductors: Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.

Insulation: Electron beam crosslinkable thin wall LSZH compound.

Optional:FRA-TW-1SU-FR (Fire resistant & Unsheathed)

Reference Standards

BS 6853 -1a

DIN 5510-1 1-4

NFF 16-101 F0

0.6/1KV Single Core Thin Wall Traction Cables

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 0.5 0.6 0.75 1.0 1.2 1.5 2.0 2.5 4.0
Maximum Conductor Resistance Ω/km 40.1 33.4 26.7 20.0 16.3 13.7 11.2 8.21 5.09
Voltage Rating KV 0.6/1.0

Mechanical and Thermal Properties

Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)

Temperature Range:-40℃ to +120℃

Dimensions And Weight

Cable Code No. of cores& Nominal Conductor Cross Sectional
Area
No.×mm²
Nominal Diameter
of Strands
No/mm
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
FRA-TW-1SU-1C0.5S 1×0.5 19/0.18 0.3 1.4 5.8
FRA-TW-1SU-1C0.6S 1×0.6 19/0.20 0.3 1.5 7
FRA-TW-1SU-1C0.75S 1×0.75 19/0.22 0.3 1.6 8.4
FRA-TW-1SU-1C1S 1×1.0 19/0.26 0.3 1.75 10
FRA-TW-1SU-1C1.2S 1×1.2 19/0.28 0.3 2.0 13
FRA-TW-1SU-1C1.5S 1×1.5 19/0.30 0.3 2.15 16
FRA-TW-1SU-1C2S 1×2.0 37/0.25 0.4 2.4 19
FRA-TW-1SU-1C2.5S 1×2.5 19/0.40 0.4 2.75 26
FRA-TW-1SU-1C4S 1×4.0 56/0.30 0.4 3.35 40

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information