Mining Cable
Type W Type G Type G-GC more

Mining Cable

N3GHSSYCY Medium-Voltage Cable

 

 

Applications

N3GHSSYCY Medium-Voltage Cables are used for the connection of mobile operatingequipment, in mines and

undergroundexcavations with hazardous environments,in stationary operation, e.g.high-voltage transformers in

mining andtunnelling.

Standards

VDE 0250 Part 605

Construction

N3GHSSYCY Medium-Voltage Cable

Conductors: Flexible strandedcopper conductor, class 5 according to DIN VDE 0295.

Insulation: EPR compound type 3GI3.

Electrical Field Control:Inner and outer semiconductive layer ofsemiconductive rubber, for 6 kV

outersemiconductive layer only.

Pilot Cores:Stranded copper conductor with EPR insulation.

Earth Conductor: Spiral ofcopper wiresover the outer semi-conductivelayer of the cores.

InnerSheath: PVC compound type YM5.

Monitoring Conductor: Conductive tape serving and overallconcentric Cu wire spinning.

Intermediate Sheath: PVCcompound type YM5.

Armour:Braid of galvanized steel wires.

Outer Sheath: PVC compound type YM5.

Dimensions and Weight

3.6/6kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No. ×mm² mm mm kg/km
3×25+3×16/3E+3×2.5ST+UEL 49.0 53.0 4190
3×35+3×16/3E+3×2.5ST+UEL 52.0 56.0 4800
3×50+3×25/3E+3×2.5ST+UEL 55.0 59.0 5600
3×70+3×35/3E+3×2.5ST+UEL 59.0 63.0 6650
3×95+3×50/3E+3×2.5ST+UEL 63.0 67.0 7940

6/10kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No. ×mm² mm mm kg/km
3×25+3×16/3E+3×2.5ST+UEL 55.0. 58.0 5300
3×35+3×16/3E+3×2.5ST+UEL 58.0 61.0 5910
3×50+3×25/3E+3×2.5ST+UEL 61.0 65.0 6790
3×70+3×35/3E+3×2.5ST+UEL 65.0 69.0 7860
3×95+3×50/3E+3×2.5ST+UEL 68.0 73.0 9180

8.7/15kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No. ×mm² mm mm kg/km
3×25+3×16/3E+3×2.5ST+UEL 58.0 62.0 6810
3×35+3×16/3E+3×2.5ST+UEL 61.0 65.0 7850
3×50+3×25/3E+3×2.5ST+UEL 64.7 68.7 9130
3×70+3×35/3E+3×2.5ST+UEL 67.9 71.9 10750
3×95+3×50/3E+3×2.5ST+UEL 72.4 76.4 12290

12/20kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No. ×mm² mm mm kg/km
3×25+3×16/3E+3×2.5ST+UEL 62.3 66.3 8790
3×35+3×16/3E+3×2.5ST+UEL 65.3 69.3 9930
3×50+3×25/3E+3×2.5ST+UEL 69.0 73.0 11360
3×70+3×35/3E+3×2.5ST+UEL 72.2 76.2 13100
3×95+3×50/3E+3×2.5ST+UEL 76.8 80.8 14750

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information