Mining Cable
Type W Type G Type G-GC more

Mining Cable

(N)TSCGECWOEU Medium-Voltage Trailing Cable

 

 

Applications

(N)TSCGECWOEU Medium-Voltage Trailing Cables are used for the connection of electrical equipment, in

minesand underground excavations with hazardousenvironments under particularly high mechanical loads,e.g.

high-voltage transformers on power lines inunderground mining and tunnelling.

Standards

Based on VDE 0250 Part 813

Construction

(N)TSCGECWOEU Medium-Voltage Trailing Cable

Conductors:

Flexible stranded copper conductor, class 5 according to DIN VDE 0295.

Inner Conductor Layer:

Special rubber compound, conductive.

Insulation:

Rubber type 3GI3.

Outer Conductor Layer:

Special rubber compound, conductive, easy strippable.

Pilot Cores (optional):

Tinned copper conductor with EPR insulation.

Earth Conductor: Spiral of tinnedcopper wires.

InnerSheath: Rubber type GM1b.

Monitoring Shield/Armour:Braided armour of combined copper-steel wires; or wrap of copper andsteel wires,

copper tape in opposite direction, reinforcing tape.

Outer Sheath: Rubber type 5GM5.

Dimensions and Weight

6/10kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No.×mm² mm mm kg/km
3×25+3×16/3E+3×2.5ST+6UEL 48.0 52.0 3500
3×35+3×16/3E+3×2.5ST+6UEL 51.0 55.0 3750
3×50+3×25/3E+3×2.5ST+6UEL 56.0 60.0 4720
3×95+3×50/3E+3×2.5ST+6UEL 66.0 71.0 7260
3×120+3×70/3E+6UEL 70.0 75.0 9700
3×150+3×70/3E+6UEL 73.0 78.0 9950
12/20 (24) kV
Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No.×mm² mm mm kg/km
3×25+3×25/3E+6UEL 62.0 67.0 5800
3×95+3×50/3E+6UEL 74.0 78.0 11000
3×120+3×70/3E+6UEL 80.0 85.0 13000

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information