| Mining Cable | |||
| Type W | Type G | Type G-GC | more |
Mining Cable
Type W Single Conductor Portable Power Cable 2kV
Applications:
Type W Single Conductor Portable Power Cables are designed for use on electric mining locomotives and
other mobile equipment of the gathering-reel type, where the cable must withstand constant flexing and
reeling.
Standards:
ICEA S-75-381/NEMA WC 58
ASTM B 172ASTM B 33
CAN/CSA C22.2 No.96
Construction:

Conductors: Stranded annealed tinned copper conductor.
Insulation:EPR.
Reinforcement: A layer of polyester braid, applied between the insulation and sheath for mechanical strength.
Sheath: Chlorinated Polyethylene(CPE), black. Other sheath materials can be offered as an option.
Options:
Other jacket materials such as CSP/PCP/NBR/PVC are available upon reques.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.
Mechanical and Thermal Properties:
Minimum Bending Radius: 6×OD
Maximum Operating Temperature: +90℃
Dimensions and Weight:
| Construction | No. of Strands | Nominal Insulation Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity | |||
|---|---|---|---|---|---|---|---|---|
| No. of cores×AWG/kcmil | inch | mm | inch | mm | lbs/kft | kg/km | A | |
| 1×8 | 133 | 0.060 | 1.5 | 0.44 | 11.2 | 150 | 223 | 83 |
| 1×6 | 168 | 0.060 | 1.5 | 0.51 | 13.0 | 205 | 305 | 109 |
| 1×4 | 259 | 0.060 | 1.5 | 0.57 | 14.5 | 280 | 417 | 145 |
| 1×3 | 329 | 0.060 | 1.5 | 0.63 | 16.0 | 350 | 521 | 167 |
| 1×2 | 259 | 0.060 | 1.5 | 0.66 | 16.8 | 370 | 550 | 192 |
| 1×1 | 329 | 0.080 | 2.0 | 0.74 | 18.8 | 500 | 744 | 223 |
| 1×1/0 | 259 | 0.080 | 2.0 | 0.77 | 19.6 | 550 | 818 | 258 |
| 1×2/0 | 329 | 0.080 | 2.0 | 0.82 | 20.1 | 660 | 982 | 298 |
| 1×3/0 | 427 | 0.080 | 2.0 | 0.87 | 22.1 | 830 | 1235 | 345 |
| 1×4/0 | 532 | 0.080 | 2.0 | 0.93 | 23.6 | 950 | 1413 | 400 |
| 1×250 | 608 | 0.095 | 2.4 | 1.03 | 26.2 | 1240 | 1845 | 445 |
| 1×300 | 741 | 0.095 | 2.4 | 1.09 | 27.7 | 1400 | 2083 | 500 |
| 1×350 | 855 | 0.095 | 2.4 | 1.15 | 29.2 | 1480 | 2202 | 552 |
| 1×500 | 1221 | 0.095 | 2.4 | 1.31 | 33.3 | 2140 | 3184 | 695 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information