IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

UKOOA TYPE LA 600/1000V Flame Retardant

Application

Marine cables are designed for fixed installation for power, control and lighting in both and safe areas,

emergency and critical offshore applications where cable protection is required.

Standards

BS 6883/BS 7917/UKOOA

IEC 60332-3-22 CAT. A

IEC 60332-1

IEC 60754-1 & IEC 60754-2

IEC 61034-1 & IEC 61034-2

Construction

Conductors:Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS 6360/IEC 60228.

Insulation:EPR complying with BS7655 GP4 

Bedding:CSP – SW2 compound complying with BS 7655.

Armour :Tinned Phosphor Bronze Wire Braid to BS2873-PB102 (now BS EN 12166) 

Outer Sheath :CSP – SW2 compound complying with BS 7655.

Dimensions and Weight

Construction
No. of cores×Cross section
Nominal Insulation Thickness
Nominal Thickness of Inner Sheath 
Nominal Thickness of Outer Sheath 
Nominal Overall Diameter
Approx. Weight
mm² mm mm mm mm kg/km
1×1.0 0.8 1.1 1.2 9.5 150
1×1.5 0.8 1.1 1.2 9.8 170
1×2.5 0.8 1.1 1.2 10.2 190
1×4 1.0 1.1 1.2 11.3 260
1×6 1.0 1.1 1.2 11.8 340
1×10 1.0 1.1 1.2 13.0 390
1×16 1.0 1.1 1.2 14.2 480
1×25 1.2 1.1 1.2 16.8 565
1×35 1.2 1.1 1.3 17.9 740
1×50 1.4 1.1 1.4 19.7 940
1×70 1.4 1.0 1.4 21.9 1270
1×95 1.6 1.2 1.4 24.5 1500
1×120 1.6 1.4 1.6 26.6 1750
1×150 1.8 1.6 1.8 29.0 2200
1×185 2.0 1.8 2.1 32.6 2700
1×240 2.2 1.3 1.5 36.0 3400
1×300 2.4 1.5 1.7 39.2 4200
1×400 2.6 1.7 2.0 43.7 5700
1×500 2.8 1.2 1.3 48.1 7200
1×630 2.8 1.0 1.2 52.3 8840