IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Power Distribution Cables

600/1000V Single conductor Type T/N distribution cables

Construction

Conductor:Stranded copper conductor tin or alloy coated where necessary for the application , conductor per

ASTM or IEC 60228.

Separator tape: optional

Insulation: Polyvinylchloride(PVC)/nylon according to IEEE 1580 2010 Type T/N,Type X, E, T, S, P, LSX and LSE

as option.

Shielding: optional

Jacket: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or

TPO jacket as option (optional for Type P with HD thicknesses).

Armor: optional and shall be nonmagnetic

Sheath:

Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or TPO

sheath as option (optional except for tinned copper braid armoured cables).

Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO

jacket/sheath.

Table B.3—Typical dimensions and weights; single-, two-, three-, and four-conductor 600/1000 V; Type T/N distribution cables


Number of conductors
AWG /kcmil Unarmored Armored Armored and sheathed
Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft)

1

14 0.21 31 0.27 44 0.37 74

1

12 0.23 41 0.29 54 0.39 87

1

10 0.26 58 0.32 74 0.42 110

1

8 0.32 90 0.38 108 0.48 149

1

6 0.34 123 0.4 141 0.5 184

1

4 0.42 188 0.48 212 0.61 280

1

1 0.58 364 0.64 395 0.76 476

1

1/0 0.63 440 0.69 473 0.81 560

1

2/0 0.67 536 0.73 571 0.89 696

1

3/0 0.73 653 0.79 690 0.95 824

1

4/0 0.79 801 0.85 841 1.01 985

1

250 0.89 977 0.95 1022 1.12 1192

1

300 0.96 1163 1.02 1213 1.19 1394

1

350 1 1315 1.06 1365 1.23 1553

1

400 1.05 1505 1.11 1558 1.28 1753

1

500 1.13 1811 1.19 1867 1.36 2076

1

600 1.24 2225 1.3 2290 1.47 2517

1

750 1.34 2686 1.4 2757 1.57 3001

1

1000 1.49 3530 1.55 3608 1.78 3978

NOTE—These values are for reference purposes only and should not be construed as requirements. Dimensions are based on the use of Class B conductors. Weights of armored constructions are based on aluminum braid armor. It is recommended that the user/specifier contact the manuf acturer for manufacturer specific values.

The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information