| IEC60092 Offshore & Marine Cables | |||
| MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
Marine Cable
RG59 Armoured Coaxial Cable
Applications :
RG59 Armoured Coaxial Cable are suitable for installation on board of ships and other indoor marine
environments.
Standards :
IEC 60092-350
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606
Construction :
Conductors : 20AWG solid bare copper.
Insulation : Foam PE.
Shielding1 : Al/Polyester/Al tape.
Shielding2 : Tinned copper braid.
Bedding : Low smoke and halogen-free polyolefin, coloured black.
Armour : Copper wire braid.
Outer Sheath : Low smoke and halogen-free polyolefin.
Electrical Characteristics :
-
AWG 20 Nominal Conductor Diameter mm 0.8 Impedance Ω 75+/-5 Nominal Attenuation@100MHz dB/100m 7.6 Nominal Attenuation@270MHz dB/100m 12.5 Nominal Attenuation@540MHz dB/100m 17.9 Nominal Attenuation@720MHz dB/100m 20.9 Nominal Attenuation@750MHz dB/100m 21.3 Nominal Attenuation@1000MHz dB/100m 24.9 Capacitance pF/m 53.5 Velocity of Propagation % 83 Conductor DCR Ω/km 32.8 Shield DCR Ω/km 12.5 Inductance μH/m 0.318 Time Delay ns/m 4.0
Mechanical and Thermal Properties :
Bending Radius : 15×OD.
Temperature Range : -30℃ ~ +75℃.
Dimensions and Weight :
| Nominal Inner Conductor Diameter mm |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
|---|---|---|---|---|
| 0.8 | 1.4 | 1.2 | 10.0 | 177 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information