IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Marine Cable

RG213 Armoured Coaxial Cable

Applications :

  • RG213 Armoured Coaxial Cable are suitable for installation on board of ships and other indoor marine

 

  • environments.

Standards :

IEC 60092-350

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606

IEC60092 Offshore & Marine CablesIEC60092 Offshore & Marine Cables

  • Construction :

Conductors : 13AWG tinned copper.

Insulation : PE.

Shielding : Tinned copper braid.

Bedding : Low smoke and halogen-free polyolefin, coloured black.

Armour : Copper wire braid.

Outer Sheath : Low smoke and halogen-free polyolefin.

Electrical Characteristics :

  • AWG 13
    Conductor Construction No./Diameter of Wires -/mm 19/0.18
    Nominal Conductor Diameter mm 0.89
    Impedance Ω 50+/-3
    Nominal Attenuation@100MHz dB/100m 15.7
    Nominal Attenuation@200MHz dB/100m 22.3
    Nominal Attenuation@400MHz dB/100m 32.8
    Nominal Attenuation@700MHz dB/100m 46.6
    Nominal Attenuation@900MHz dB/100m 54.1
    Nominal Attenuation@1000MHz dB/100m 56.1
    Capacitance pF/m 101
    Velocity of Propagation % 66
    Conductor DCR Ω/km 35.4
    Inductance μH/m 0.246
    Time Delay ns/m 5.0

Mechanical and Thermal Properties :

Bending Radius : 15×OD.

Temperature Range : -30℃ ~ +75℃.

Dimensions and Weight :

Nominal Inner Conductor Diameter
mm
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight kg/km
0.89 1.0 1.14 8.6 149

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information