Water Blocked P6 or P6/P13 BFOU 3.6/6kV

Applications

Standards

IEC 60092-353

IEC 60092-360

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606

VG 95218 part 29

Water Blocked P6 or P6/P13 BFOU 3.6/6kV

Electrical Characteristics

 

Ambient Temperature Correction Factors

Mechanical and Thermal Properties

Bending Radius :15×OD (during installation); 9×OD (fixed installed).

Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight

Construction No. of cores×Cross section mm² Nominal Insulation Thickness
mm
Nominal Bedding Thickness
mm
Nominal Inner Sheath Thickness
mm
Nominal Outer Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight kg/km
1×16 2.5 1.5 1.2 1 26.8±2 998
1×25 2.5 1.6 1.2 1.2 28.7±2 1166
1×35 2.5 1.6 1.2 1.2 30.0±2 1323
1×50 2.5 1.7 1.3 1.2 31.5±2 1533
1×70 2.5 1.7 1.3 1.2 33.3±2 1827
1×95 2.5 1.8 1.4 1.4 36.0±2 2216
1×120 2.5 1.9 1.4 1.4 37.7±2 2552
1×150 2.5 1.9 1.4 1.4 39.7±2 3035
1×185 2.5 2 1.5 1.4 41.9±2 3539
1×240 2.6 2.1 1.6 1.6 45.4±2 4305
1×300 2.8 2.2 1.6 1.6 47.9±2 5051
1×400 3 2.3 1.7 1.6 51.3±2 6101
1×500 3.2 2.5 1.8 1.6 55.3±2 7382
1×630 3.2 2.6 1.9 1.6 59.7±2 9062
3×16 2.5 2.3 1.7 1 49.8±2 3728
3×25 2.5 2.5 1.8 1.2 53.9±2 4389
3×35 2.5 2.6 1.9 1.2 57.1±2 5061
3×50 2.5 2.7 1.9 1.2 59.8±2 5765
3×70 2.5 2.8 2 1.2 64.0±2 6920
3×95 2.5 3 2.1 1.4 69.0±2 8316
3×120 2.5 3.1 2.2 1.4 72.9±2 9608
3×150 2.5 3.3 2.3 1.4 76.8±2 10983
3×185 2.5 3.4 2.4 1.4 81.4±2 12611
3×240 2.6 3.7 2.6 1.6 89.5±2 15425
3×300 2.8 3.9 2.8 1.6 95.1±2 17987
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information