| Marine Cables | |||
| MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
Marine Cable
P4 or P4/P11 RFOU/TFOU 8.7/15KV
Applications :
P4 or P4/P11 RFOU/TFOU 8.7/15KV Marine cables are flame retardant, low smoke, halogen free and mud
resistant, used for fixed installation for medium voltage power.
Standards :
IEC 60092-353
IEC 60092-360
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606
Construction :
Conductors : Circular tinned annealed stranded copper to IEC 60228 class 2.
Conductor Screen : Semi conducting material.
Insulation : Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).
Insulation Screen : Semi conducting material and tinned copper wire braid.
Bedding : Halogen free compound.
Armour : Tinned copper wire braid.
Outer Sheath :Halogen free thermosetting compound, SHF2 (for TYPE P4), or halogen free mud resistant
thermosetting compound, SHF MUD (for TYPE P4/P11), coloured red.
Electrical Characteristics :
-
Nominal Cross Section Area mm² 25 35 50 70 95 120 Nominal Conductor Diameter mm 6.5 7.4 8.7 10.3 12.2 13.8 Maximum DC Resistant@20℃ Ω/km 0.734 0.529 0.391 0.27 0.195 0.154 Continuous Current Rating@45℃1 Core A 127 157 196 242 293 339 Continuous Current Rating@45℃3 Core A 89 110 137 169 205 237 Short Circuit Current 1s A 3580 5010 7150 10020 13590 17170 Operating Voltage KV 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 -
Nominal Cross Section Area mm² 150 185 240 300 400 500 630 Nominal Conductor Diameter mm 15.1 17.0 19.6 21.9 24.5 27.5 32.3 Maximum DC Resistant@20℃ Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286 Continuous Current Rating@45℃1 Core A 389 444 522 601 690 780 890 Continuous Current Rating@45℃3 Core A 272 311 365 421 483 546 623 Short Circuit Current 1s A 21460 26470 34340 42930 57230 71540 90140 Operating Voltage KV 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15
Ambient Temperature Correction Factors :
-
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80 Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties :
Bending Radius :15×OD (during installation); 9×OD (fixed installed).
Temperature Range : -20℃ ~ +90℃.
Dimensions and Weight :
| Construction No. of cores×Cross section (mm²) |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
|
|---|---|---|---|---|---|
| Inner | Outer | ||||
| 1×25 | 4.5 | 28.4 | 1305 | ||
| 1×35 | 4.5 | 29.3 | 1430 | ||
| 1×50 | 4.5 | 30.7 | 1620 | ||
| 1×70 | 4.5 | 32.4 | 1900 | ||
| 1×95 | 4.5 | 34.4 | 2250 | ||
| 1×120 | 4.5 | 36.6 | 2625 | ||
| 1×150 | 4.5 | 38.1 | 2940 | ||
| 1×185 | 4.5 | 40.6 | 3545 | ||
| 1×240 | 4.5 | 43.4 | 4220 | ||
| 1×300 | 4.5 | 46.3 | 5070 | ||
| 1×400 | 4.5 | 50.2 | 5760 | ||
| 1×500 | 4.5 | 53.6 | 6880 | ||
| 1×630 | 4.5 | 57.9 | 8460 | ||
| 3×25 | 4.5 | 55.3 | 4725 | ||
| 3×35 | 4.5 | 57.5 | 5215 | ||
| 3×50 | 4.5 | 60.6 | 5960 | ||
| 3×70 | 4.5 | 64.4 | 7035 | ||
| 3×95 | 4.5 | 68.7 | 8370 | ||
| 3×120 | 4.5 | 72.7 | 9745 | ||
| 3×150 | 4.5 | 76.8 | 11140 | ||
| 3×185 | 4.5 | 84.2 | 13490 | ||
| 3×240 | 4.5 | 90.6 | 15860 | ||
| 3×300 | 4.5 | 96.6 | 18320 | ||
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information