Marine Cable
P30 RFOU-HCF / TFOU-HCF 6/10(12) kV
Applications :
P30 RFOU-HCF / TFOU-HCF 6/10(12) kVMarine cables are fire resistant, flame retardant, low smoke and halogen
free, used for emergency control, power and lighting systems that need to be operational during a 1100℃
hydrocarbon fire.
Standards :
IEC 60092-354
IEC 60092-360
IEC 60332-1
IEC 60331-21
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606

Construction :
Conductors : Circular tinned annealed stranded copper to IEC 60228 class 2.
Conductor Screen : Semi conducting material.
Insulation : Halogen-free EPR. XLPE can be offered as an option.
Insulation Screen : Semi conducting material and tinned copper wire braid.
Bedding : Halogen free compound.
Armour : Tinned copper wire braid.
Outer Sheath1 : Halogen free thermosetting compound, SHF2, coloured red.
HC-fire protection : Extruded thermoplastic fire protection compound.
Taping : Lapped glass fibre tape.
Outer Sheath2 : Flame retardant halogen-free thermoplastic compound, SHF1, coloured red.
Optional :
P31 RFOU-HCF / TFOU-HCF 8.7/15kV
P32 RFOU-HCF / TFOU-HCF 12/20(24) kV
P33 RFOU-HCF / TFOU-HCF 18/30(36) kV
Electrical Characteristics :
-
Nominal Cross Section Area mm² 70 95 120 150 185 240 300 Nominal Conductor Diameter mm 10.3 12.2 13.8 15.1 17.0 19.6 21.9 Maximum DC Resistant@20℃ Ω/km 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 Continuous Current Rating@45℃1 Core A 242 293 339 389 444 522 601 Continuous Current Rating@45℃3 Core A 169 205 237 272 311 365 421 Short Circuit Current 1s A 10020 13590 17170 21460 26470 34340 42930 Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10
Ambient Temperature Correction Factors :
-
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80 Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties :
Bending Radius : 25×OD (during installation); 12×OD (fixed installed).
Temperature Range : -20℃ ~ +90℃.
Dimensions and Weight :
| Construction No. of cores×Cross section (mm²) |
Nominal Insulation Thickness mm |
Nominal Diameter Over Bedding mm |
Nominal Diameter Over Sheath1 mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
|---|---|---|---|---|---|
| 1×70 | 3.4 | 23.5 | 30.0 | 62.0 | 5220 |
| 1×95 | 3.4 | 25.5 | 32.0 | 64.5 | 5900 |
| 1×120 | 3.4 | 27.5 | 34.0 | 66.5 | 6340 |
| 1×150 | 3.4 | 28.5 | 35.0 | 67.5 | 6670 |
| 1×185 | 3.4 | 30.5 | 36.5 | 69.0 | 7320 |
| 1×240 | 3.4 | 33.0 | 39.0 | 72.0 | 8250 |
| 1×300 | 3.4 | 35.0 | 41.5 | 74.5 | 9280 |
| 3×50 | 3.4 | 47.0 | 55.0 | 89.0 | 10970 |
| 3×95 | 3.4 | 54.0 | 62.5 | 97.0 | 14230 |
| 3×150 | 3.4 | 60.0 | 70.5 | 106.0 | 17400 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information