Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Marine Cable

P2 or P2/P9 RFOU/TFOU 3.6/6KV

Applications :

P2 or P2/P9 RFOU/TFOU 3.6/6KV Marine cables are flame retardant, low smoke, halogen free and mud resistant,

used for fixed installation for medium voltage power.

Standards :

IEC 60092-353

IEC 60092-360

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606

BS 6883&BS7917 Offshore & Marine cablesBS 6883&BS7917 Offshore & Marine cables

Construction :

Conductors : Circular tinned annealed stranded copper to IEC 60228 class 2.

Conductor Screen : Semi conducting material.

Insulation : Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).

Insulation Screen : Semi conducting material and tinned copper wire braid.

Bedding : Halogen free compound.

Armour : Tinned copper wire braid.

Outer Sheath : Halogen free thermosetting compound, SHF2 (for TYPE P2), or halogen free mud resistant

thermosetting compound, SHF MUD (for TYPE P2/P9),coloured red.

Electrical Characteristics :

Ambient Temperature Correction Factors :

Mechanical and Thermal Properties :

Bending Radius :15×OD (during installation); 9×OD (fixed installed).

Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight :

Construction No. of cores×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
Inner Outer
1×16 2.5 1.0 1.6 22.8 780
1×25 2.5 1.0 1.6 24.0 1020
1×35 2.5 1.0 1.7 25.1 1155
1×50 2.5 1.0 1.7 26.3 1320
1×70 2.5 1.0 1.8 28.2 1595
1×95 2.5 1.0 1.9 30.0 1905
1×120 2.5 1.0 1.9 31.8 2235
1×150 2.5 1.2 2.0 33.5 2550
1×185 2.5 1.2 2.1 35.4 3015
1×240 2.6 1.2 2.2 38.8 3725
1×300 2.8 1.2 2.3 42.3 4625
1×400 3.0 1.4 2.5 46.6 5420
1×500 3.2 1.4 2.6 50.8 6610
1×630 3.2 1.4 2.8 55.1 8170
3×16 2.5 1.2 2.3 44.9 2930
3×25 2.5 1.2 2.4 45.4 3390
3×35 2.5 1.4 2.5 47.6 3820
3×50 2.5 1.4 2.6 50.9 4495
3×70 2.5 1.4 2.8 54.8 5585
3×95 2.5 1.6 2.9 58.9 6765
3×120 2.5 1.6 3.1 63.5 8165
3×150 2.5 1.6 3.2 67.4 9495
3×185 2.5 1.6 3.4 75.8 10660
3×240 2.6 1.8 3.6 82.3 11660
3×300 2.8 1.8 3.9 89.3 12940

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information