Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

M2XH-FFR

0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Power & Control Cables (Multicore)

Applications

0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Power & Control Cables

(Multicore) are used on board of ships in all locations for fixed installations where cable protection is not

required. Marine cables are fire resistant, flame retardant, low smoke & halogen free.

Standards

IEC 60092-350/360/353

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1/2

IEC 61034

Construction

0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Power & Control Cables (Multicore)

Conductors:Class 2 stranded copper conductor. Class 5 stranded conductors can be offered upon request.

Insulation:Mica tape + XLPE.

Outer Sheath:LSOH (SHF1).

Core Identification

Two cores:Blue, Brown.

Three cores:Brown, Black, Grey.

Four cores:Blue, Brown, Black, Grey.

Five cores:Blue, Brown, Black, Grey, Black.

Multi cores:White with black numbers.

Mechanical and Thermal Properties

Bending Radius for Fixed Installations:6×OD (OD>25mm); 4×OD (OD ≤25mm)

Temperature Range:-30℃ ~ +80℃

Dimensions and Weight

M2XH-FFR Multicore 0.6/1kV

Part No. Construction No. of elements×No. of cores in element×Cross section Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Nominal Weight
  mm² mm mm mm kg/km
M2XH-FFR -2C1.5 2×1.5 0.7 1.1 8.5 85
M2XH-FFR -2C2.5 2×2.5 0.7 1.1 9.5 110
M2XH-FFR -2C4 2×4 0.9 1.1 11.7 140
M2XH-FFR -2C6 2×6 0.9 1.2 13.0 230
M2XH-FFR -2C10 2×10 0.9 1.2 14.7 330
M2XH-FFR -2C16 2×16 0.9 1.3 17.0 490
M2XH-FFR -2C25 2×25 0.9 1.3 19.5 750
M2XH-FFR -2C35 2×35 0.9 1.5 22.0 990
M2XH-FFR -2C50 2×50 1.0 1.5 24.8 1340
M2XH-FFR -3C1.5 3×1.5 0.7 1.1 9.5 105
M2XH-FFR -3C2.5 3×2.5 0.7 1.1 10.0 145
M2XH-FFR -3C4 3×4 0.9 1.2 12.7 205
M2XH-FFR -3C6 3×6 0.9 1.2 13.9 270
M2XH-FFR -3C10 3×10 0.9 1.3 15.9 400
M2XH-FFR -3C16 3×16 0.9 1.3 18.4 610
M2XH-FFR -3C25 3×25 0.9 1.5 21.4 920
M2XH-FFR -3C35 3×35 0.9 1.6 24.2 1330
M2XH-FFR -3C50 3×50 1.0 1.7 27.5 1830
M2XH-FFR -3C70 3×70 1.1 1.8 32.0 2570
M2XH-FFR -3C70S 3×70 (sector shaped) 1.1 1.8 27.5 2370
M2XH-FFR -3C95 3×95 1.1 1.9 36.4 3360
M2XH-FFR -3C95S 3×95 (sector shaped) 1.1 1.9 31.1 3130
M2XH-FFR -3C120 3×120 1.2 2.1 40.7 4180
M2XH-FFR -3C120S 3×120 (sector shaped) 1.2 2.1 34.4 3930
M2XH-FFR -4C1.5 4×1.5 0.7 1.1 10.0 135
M2XH-FFR -4C2.5 4×2.5 0.7 1.1 11.2 180
M2XH-FFR -4C4 4×4 0.9 1.2 13.9 260
M2XH-FFR -4C6 4×6 0.9 1.2 15.2 350
M2XH-FFR -4C10 4×10 0.9 1.3 17.4 530
M2XH-FFR -4C16 4×16 0.9 1.4 20.2 800
M2XH-FFR -4C25 4×25 0.9 1.5 23.5 1230
M2XH-FFR -4C35 4×35 0.9 1.7 26.7 1650
M2XH-FFR -5C1.5 5×1.5 0.7 1.1 11.0 170
M2XH-FFR -7C1.5 7×1.5 0.7 1.2 12.6 210
M2XH-FFR -12C1.5 12×1.5 0.7 1.3 16.5 350
M2XH-FFR -19C1.5 19×1.5 0.7 1.4 19.6 520
M2XH-FFR -27C1.5 27×1.5 0.7 1.5 23.3 730
M2XH-FFR -37C1.5 37×1.5 0.7 1.6 26.3 980
M2XH-FFR -5C2.5 5×2.5 0.7 1.2 12.5 240
M2XH-FFR -7C2.5 7×2.5 0.7 1.2 14.1 300
M2XH-FFR -12C2.5 12×2.5 0.7 1.3 18.6 490
M2XH-FFR -19C2.5 19×2.5 0.7 1.4 22.1 750
M2XH-FFR -27C2.5 27×2.5 0.7 1.5 26.4 1060