Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

M2XCH 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Power & Control Cables (Multicore)

Applications

M2XCH 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Power & Control

Cables (Multicore) are used on board of ships in all locations for fixed installations where cable protection

is required. These cables are flame retardant, low smoke & halogen free.

Standards

IEC 60092-350/360/353

IEC 60332-1

IEC 60332-3-22

IEC 60754-1/2

IEC 61034

Construction

M2XCH 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Power & Control Cables (Multicore)

Conductors:Class 2 stranded copper conductor, round or sector shaped. Class 5 stranded conductors can be

offered upon request.

Insulation:XLPE.

Inner Covering:Lapping.

Armour:Copper wire braid.

Outer Sheath:LSOH (SHF1).

Core Identification

Two cores:Blue, Brown.

Three cores:Brown, Black, Grey.

Four cores:Blue, Brown, Black, Grey.

Five cores:Blue, Brown, Black, Grey, Black.

Multi cores:White with black numbers.

                   With yellow/green (optional)

Two cores + earth (3G):Yellow/green, Blue, Brown.

Three cores + earth (4G):Yellow/green, Brown, Black, Grey.

Four cores + earth (5G):Yellow/green, Blue, Brown, Black, Grey.

Mechanical and Thermal Properties

Bending Radius for Fixed Installations:6×OD

Temperature Range:-30℃ ~ +80℃

Dimensions and Weight

M2XCH Multicore Armoured 0.6/1kV

Part No. Construction No. of elements×No. of cores in element×Cross section Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Nominal Weight
  mm² mm mm mm kg/km
M2XCH -2C1.5 2×1.5 0.7 1.1 9.3 120
M2XCH -2C2.5 2×2.5 0.7 1.1 10.1 150
M2XCH -2C4 2×4 0.9 1.2 12.2 195
M2XCH -2C6 2×6 0.9 1.2 13.7 275
M2XCH -2C10 2×10 0.9 1.3 15.7 385
M2XCH -2C16 2×16 0.9 1.4 18.4 595
M2XCH -2C25 2×25 0.9 1.5 21.3 820
M2XCH -2C35 2×35 0.9 1.5 23.9 1140
M2XCH -2C50 2×50 1.0 1.5 26.7 1500
M2XCH -3C1.5(3G1.5) 3×(G)1.5 0.7 1.1 9.8 145
M2XCH -3C2.5(3G2.5) 3×(G)2.5 0.7 1.1 10.7 180
M2XCH -3C4 3×4 0.9 1.2 12.9 245
M2XCH -3C6 3×6 0.9 1.3 14.7 345
M2XCH -3C10 3×10 0.9 1.3 16.6 490
M2XCH -3C16 3×16 0.9 1.4 19.5 755
M2XCH -3C25 3×25 0.9 1.6 22.7 1095
M2XCH -3C35 3×35 0.9 1.6 24.9 1340
M2XCH -3C35S 3×35 (sector shaped) 0.9 1.6 22.0 1320
M2XCH -3C50 3×50 1.0 1.6 27.1 1750
M2XCH -3C50S 3×50 (sector shaped) 1.0 1.6 24.8 1820
M2XCH -3C70S 3×70 (sector shaped) 1.1 2.0 29.7 2575
M2XCH -3C95S 3×95 (sector shaped) 1.1 2.1 33.1 3435
M2XCH -3C120S 3×120 (sector shaped) 1.2 2.2 36.0 4070
M2XCH -3C150S 3×150 (sector shaped) 1.4 2.4 40.9 5435
M2XCH -4C1.5(4G1.5) 4×(G)1.5 0.7 1.1 10.5 170
M2XCH -4C2.5(4G2.5) 4×(G)2.5 0.7 1.2 11.8 225
M2XCH -4C4 4×4 0.9 1.3 14.7 335
M2XCH -4C6 4×6 0.9 1.3 16.0 425
M2XCH -4C10 4×10 0.9 1.4 18.3 625
M2XCH -4C16 4×16 0.9 1.5 21.5 935
M2XCH -4C25 4×25 0.9 1.6 24.4 1345
M2XCH -4C35 4×35 0.9 1.7 27.5 1715
M2XCH -4C35S 4×35 (sector shaped) 0.9 1.7 24.3 1700
M2XCH -4C50 4×50 1.0 1.6 29.9 2400
M2XCH -4C50S 4×50(sector shaped) 1.0 1.6 27.3 2300
M2XCH -4C70S 4×70(sector shaped) 1.1 2.1 32.8 3250
M2XCH -4C95S 4×95(sector shaped) 1.1 2.2 37.3 4390
M2XCH -5C1.5(5G1.5) 5×(G)1.5 0.7 1.2 11.7 205
M2XCH -5C2.5(5G2.5) 5×(G)2.5 0.7 1.2 12.8 265
M2XCH -5G4 5G4 0.9 1.2 15.2 360
M2XCH -6C1.5 6×1.5 0.7 1.2 12.7 240
M2XCH -7C1.5 7×1.5 0.7 1.2 12.7 260
M2XCH -8C1.5 8×1.5 0.7 1.2 15.5 340
M2XCH -10C1.5 10×1.5 0.7 1.3 16.2 390
M2XCH -12C1.5 12×1.5 0.7 1.4 16.9 440
M2XCH -16C1.5 16×1.5 0.7 1.4 18.6 550
M2XCH -19C1.5 19×1.5 0.7 1.5 19.7 620
M2XCH -24C1.5 24×1.5 0.7 1.6 22.9 800
M2XCH -5C2.5 5×2.5 0.7 1.2 12.9 290
M2XCH -7C2.5 7×2.5 0.7 1.2 14.6 390
M2XCH -12C2.5 12×2.5 0.7 1.4 18.7 610
M2XCH -19C2.5 19×2.5 0.7 1.5 21.8 870
M2XCH -24C2.5 24×2.5 0.7 1.6 25.6 1100
M2XCH -27C2.5 27×2.5 0.7 1.7 26.1 1200
M2XCH -37C2.5 37×2.5 0.7 1.9 29.2 1560