| Marine Cables | |||
| MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
Marine Cable
Cat5E UTP/FTP Armoured Data Cable
Applications :
Cat5E UTP/FTP Armoured Data Cable is a cable standard for Gigabit Ethernet and other network protocol,
suitable for basic voice and data installations up to 100 MHz. In addition, these cables are with copper wire
braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still
maintaining the flexibility of the cable.
Standards :
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606


Construction :
Conductors : 24AWG solid bare copper.
Insulation : HDPE.
Twinning : Two coloured insulated conductors twisted together to form a pair.
Bedding : Flame retardant, low smoke and halogen-free polyolefin, coloured black.
Armour : 0.2/0.3mm copper wire braid.
Outer Sheath : Low smoke and halogen-free polyolefin.
Optional :
Cat5E F/UTP : These cables have collective shielding of aluminium/Polyester tape with drain wire.
Cat5E SF/UTP :These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid
with drain wire
Electrical Characteristics :
-
AWG 18 Nominal Conductor Diameter mm 1.0 Maximum DC Resistant@20℃ Ω/100m 9.38 Maximum DCR Unbalance % 5 Maximum Mutual Capacitance pF/m 55.8 Maximum Capacitance Unbalance pF/100m 330 Characteristic Impedance@1-100MHz Ω 100+/-15 Maximum Propagation Delay Skew ns/100m 45
-
FREQ MHz Maximum Attenuation dB/100m Minimum NEXT dB Minimum PSNEXT dB Minimum ELFEXT dB/100m Minimum PSELFEXT dB/100m Minimum RL dB 0.772 1.8 67.0 64.0 66.0 63.0 — 1 2.0 65.3 62.3 63.8 60.8 20.0 4 4.1 56.3 53.3 51.7 48.7 23.0 8 5.8 51.8 48.8 45.7 42.7 24.5 10 6.5 50.3 47.3 43.8 40.8 25.0 16 8.2 47.3 44.3 39.7 36.7 25.0 20 9.3 45.8 42.8 37.7 34.7 25.0 25 10.4 44.3 41.3 35.8 32.8 24.3 31.25 11.7 42.9 39.9 33.9 30.9 23.6 62.5 17.0 38.4 35.4 27.8 24.8 21.5 100 22.0 35.3 32.3 23.8 20.8 20.1
Mechanical and Thermal Properties :
Bending Radius : 8×OD (during installation); 4×OD (fixed installed).
Temperature Range : -30℃ ~ +75℃.
Dimensions and Weight :
| Construction No. of elements×No. of cores in element×Conductor diameter (mm²) |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
|
|---|---|---|---|---|---|
| Inner | Outer | ||||
| 4×2×0.53 | 0.2 | 0.8 | 1.2 | 11.2 | 208 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information