Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control Cables

Application

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control Cables are

designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control

applications.

Standards

BS 6883

IEC 60332-3A Flame retardant

IEC 60754-1; IEC 60754-2 Corrosivity

IEC 61034-2 Smoke density

Cold bend and impact (-40°C) (on request)

CSA C22.2 No. 38-95 (on request)

Construction

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control Cables

Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.

Insulation: HF-EPR GP4 according to BS 7655 1.2.

Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting

compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)

Temperature Range: -40℃ ~ +90℃

Dimensions and Weight

Single core cables

Construction
No. of cores×Cross section
mm²
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Minimum Overall Diameter
mm
Maximum Overall Diameter
mm
Approx. Weight
kg/km
1×4 1.0 1.0 6.3 7.6 85
1×6 1.0 1.0 6.8 8.1 120
1×10 1.0 1.0 7.7 9.1 165
1×16 1.0 1.1 8.9 10.3 230
1×25 1.2 1.2 11.1 12.8 345
1×35 1.2 1.2 12.0 13.7 445
1×50 1.4 1.3 13.7 15.5 600
1×70 1.4 1.3 15.5 17.4 810
1×95 1.6 1.4 17.7 19.8 1100
1×120 1.6 1.5 19.6 22.0 1360
1×150 1.8 1.6 21.6 24.2 1650
1×185 2.0 1.7 24.0 26.6 2070
1×240 2.2 1.8 27.1 29.9 2670
1×300 2.4 1.9 30.0 33.2 3340

Multicore cables

Construction
No. of cores×Cross section

mm²

Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Minimum Overall Diameter
mm
Maximum Overall Diameter
mm
Approx. Weight
kg/km
2×1 0.8 1.0 7.5 8.8 100
2×1.5 0.8 1.1 8.2 9.6 125
2×2.5 0.8 1.1 9.0 10.4 160
2×4 1.0 1.2 11.0 12.7 235
2×6 1.0 1.2 12.1 13.8 300
2×10 1.0 1.3 14.1 15.9 415
2×16 1.0 1.4 16.3 18.3 590
2×25 1.2 1.5 20.4 22.9 890
2×35 1.2 1.6 22.4 24.9 1150
2×50 1.4 1.7 25.7 28.4 1570
2×70 1.4 1.9 29.6 32.7 2140
2×95 1.6 2.1 34.1 37.4 2930
2×120 1.6 2.2 37.7 41.1 3600
3×1 0.8 1.1 8.2 9.5 110
3×1.5 0.8 1.1 8.7 10.1 150
3×2.5 0.8 1.1 9.6 11.0 190
3×4 1.0 1.2 11.7 13.4 280
3×6 1.0 1.2 12.9 14.7 370
3×10 1.0 1.3 15.0 17.0 505
3×16 1.0 1.4 17.4 19.4 750
3×25 1.2 1.6 22.0 24.6 1150
3×35 1.2 1.7 24.1 26.7 1490
3×50 1.4 1.8 27.7 30.5 2030
3×70 1.4 2.0 31.8 35.1 2790
3×95 1.6 2.2 36.7 40.1 3820
3×120 1.6 2.3 40.5 44.4 4710
3×150 1.8 2.5 44.9 49.0 5710
3×185 2.0 2.7 50.1 54.6 7180
3×240 2.2 2.9 56.7 61.5 9310
3×300 2.4 3.2 63.1 68.6 10860

Construction
No. of cores×Cross section

mm²

Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Minimum Overall Diameter
mm
Maximum Overall Diameter
mm
Approx. Weight
kg/km
4×1 0.8 1.1 8.9 10.3 140
4×1.5 0.8 1.1 9.5 10.9 175
4×2.5 0.8 1.1 10.5 12.1 225
4×4 1.0 1.2 12.9 14.6 340
4×6 1.0 1.3 14.4 16.2 465
4×10 1.0 1.4 16.7 18.7 640
4×16 1.0 1.5 19.4 21.8 960
4×25 1.2 1.7 24.5 27.1 1550
4×35 1.2 1.8 26.8 29.5 1920
4×50 1.4 1.9 30.8 34.0 2600
4×70 1.4 2.1 35.4 38.8 3570
4×95 1.6 2.3 40.8 44.7 4900
4×120 1.6 2.5 45.2 49.3 6070
4×150 1.8 2.7 50.1 54.7 7360
4×185 2.0 2.9 55.8 60.7 9260
4×240 2.2 3.2 63.4 68.9 12030
5×1.5 0.8 1.1 10.4 12.0 200
7×1.5 0.8 1.2 11.5 13.2 255
12×1.5 0.8 1.3 15.2 17.2 405
19×1.5 0.8 1.4 18.0 20.1 600
27×1.5 0.8 1.6 21.9 24.5 850
37×1.5 0.8 1.7 24.7 27.3 1120
5×2.5 0.8 1.2 11.7 13.3 270
7×2.5 0.8 1.2 12.7 14.4 335
12×2.5 0.8 1.4 17.1 19.1 550
19×2.5 0.8 1.5 20.2 22.7 830

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information