| Firetox Flame Retardant Cables | |||
Flame Retardant Coaxial Cables
        
      Flame Retardant RG59 Coaxial cables
Application:
Flame Retardant RG59 Coaxial cables are designed for CCTV, security, smoke detection and evacuation
monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen
low smoke construction, this cable is ideal for use in public, commercial and industrial environments.
Standards
![]()
Basic design to MIL-C-17

Fire Performance
Flame Retardance (Single Vertical Wire Test)  | 
                          EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2- 1*; DIN VDE 0482-265-2-1*  | 
                        
|---|---|
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)  | 
                          EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- 004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2- 4  | 
                        
| Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* | 
No Corrosive Gas Emission  | 
                          IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* | 
minimum Smoke Emission  | 
                          IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*  | 
                        
| No Toxic gases | NES 02-713; NF C 20-454 | 
CPR Compliance  | 
                          Eca  | 
                        
Note: Asterisk * denotes superseded standard.
Cable Construction
Conductors: Copper clad steel, solid according to IEC(EN) 60228 class 1.
Insulation: PE compound.
Overall Screen: Plain copper wire braid
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1(Thermosetting LSZH compound
type SW2-SW4 as per BS 7655-2.6 can be offered.)
Physical And Thermal Properties
Temperature range during operation (fixed state): -30°C - +70°C
Temperature range during installation (mobile state): -5ºC - +60ºC
Minimum bending radius: 8 x Overall Diameter
Electrical Properties
| Impedance | 75±5Ω | 
|---|---|
| Capacitance | 67 NF/Km | 
| Velocity ratio(%) | 66 | 
| Insulation resistance | >2000 mohm.Km | 
| Shield coverage | 95% | 
| DC resistance | |
| Inner conductor | 158 Ω/km | 
| Outer conductor | 9.0 Ω/km | 
Att enuation
| Frequency(MHz) | Attenuation (dB/100 m) | Attenuation (dB/100ft) | 
|---|---|---|
| 50 | 7.4 | 2.26 | 
| 100 | 10.7 | 3.26 | 
| 200 | 15.7 | 4.79 | 
| 400 | 22.7 | 6.92 | 
| 500 | 25.7 | 7.84 | 
| 600 | 28.7 | 8.75 | 
| 860 | 34.8 | 10.61 | 
| 1000 | 38.0 | 11.59 | 
Return Loss
| Frequency(MHz) | Return Loss (dB) | 
|---|---|
| 30-300 mHz | >31dB | 
| 300-600 mHz | >28dB | 
| 600-900 mHz | >24dB | 
Construction Parameters
| Cable  Code  | 
                          Conductor  Diameter  | 
                          Nominal Insulation Diameter | Nominal  Screen No.x Diameter  | 
                          Nominal Overall Diameter | Approx. Weight | 
|---|---|---|---|---|---|
| mm | mm | No. x mm | mm | kg/km | |
| RG59 B/U | 0.58 ± 0.03 | 3.70 ± 0.10 m | 120 x 0.15 | 6.20 | 60.3 | 
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information