| Firetox Flame Retardant Cables | |||
Firetox Flame Retardant Cables
      
      LSZH Flame Retardant CAT6 Data Cables
FTX-CAT6U/UTP4P23LH
FTX-CAT6F/UTP4P23LH
 FTX-CAT6SF/UTP4P23LH
  
APPLICATION
Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT,
100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, LSZH Flame Retardant CAT6 Data
cables can be offered with copper wire braid armoured & flame retardant outer sheath, providing additional
mechanically protection still maintaining the flexibility of the cable.
STANDARDS
![]()
ISO/IEC 11801 EN 50173 ANSI/TIA/EIA 568

Approvals:
ETL Certification (103488703CRT-001a, 103488703CRT-001d,)
FIRE PERFORMANCE
| Flame Retardance (Single vertical wire or cable test) | IEC 60332-1-2; EN 60332-1-2  | 
  
|---|---|
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)  | 
    IEC 60332-3-24; EN 60332-3-24  | 
  
Halogen Free  | 
    IEC 60754-1; EN 50267-2-1  | 
  
No Corrosive Gas Emission  | 
    IEC 60754-2; EN 50267-2-2  | 
  
Minimum Smoke Emission  | 
    IEC 61034-2; EN 61034-2  | 
  
CPR Compliance  | 
    Eca  | 
  
CABLE CONSTRUCTION

Conductors : 23AWG solid bare copper.
Insulation : PE.
Twinning : Two coloured insulated conductors twisted together to form a pair.
Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound
type SW2-SW4 as per BS 7655-2.6 can be offered).
Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite
properties can be offered as option.
Cat6 F/UTP : These cables have collective shielding of Aluminium/polyester tape with drain wire.
Cat6 SF/UTP : These cables have double collective shielding of Aluminium/polyester tape & copper wire braid
with drain wire.
PHYSICAL AND THERMAL PROPERTIES
Temperature range : -30°C - +75°C
Minimum bending radius during installation (mobile state) : 8 x Overall Diameter
Minimum bending radius during operation (fixed state) : 4 x Overall Diameter
ELECTRICAL PROPERTIES
| AWG | 
  | 
    23  | 
  
|---|---|---|
Nominal Conductor Diameter  | 
    mm  | 
    0.56/0.57/0.58  | 
  
Maximum DC Resistance@20°C  | 
    Ω/100m  | 
    9.38  | 
  
Maximum DCR Unbalance  | 
    %  | 
    3  | 
  
Maximum Mutual Capacitance  | 
    pF/m  | 
    5.8  | 
  
Maximum Capacitance Unbalance  | 
    pF/100m  | 
    30  | 
  
Characteristic Impedance@1-100MHz  | 
    Ω  | 
    100±15  | 
  
Maximum Propagation Delay Skew  | 
    ns/100m  | 
    18  | 
  
TRANSMISSION PROPERTIES
| FREQ | Attenuation  | 
    NEXT  | 
    PSNEXT  | 
    ELFEXT  | 
    PSELFEXT  | 
    RL  | 
  
|---|---|---|---|---|---|---|
MHz  | 
    dB/100m  | 
    dB  | 
    dB  | 
    dB/100m  | 
    dB/100m  | 
    dB  | 
  
0.772  | 
    1.8  | 
    76.0  | 
    74.  | 
    70.0  | 
    67.0  | 
    —  | 
  
1  | 
    2.0  | 
    74.3  | 
    72.3  | 
    67.8  | 
    64.8  | 
    20.0  | 
  
4  | 
    3.8  | 
    65.3  | 
    63.3  | 
    55.7  | 
    52.7  | 
    23.0  | 
  
8  | 
    5.3  | 
    60.8  | 
    58.8  | 
    49.7  | 
    46.7  | 
    24.5  | 
  
10  | 
    6.0  | 
    59.3  | 
    57.3  | 
    47.8  | 
    44.8  | 
    25.0  | 
  
16  | 
    7.6  | 
    56.3  | 
    54.3  | 
    43.7  | 
    40.7  | 
    25.0  | 
  
20  | 
    8.5  | 
    54.8  | 
    52.8  | 
    41.7  | 
    38.7  | 
    25.0  | 
  
25  | 
    9.5  | 
    53.3  | 
    51.3  | 
    39.8  | 
    36.8  | 
    24.3  | 
  
31.25  | 
    10.7  | 
    51.9  | 
    49.9  | 
    37.9  | 
    34.9  | 
    23.6  | 
  
62.5  | 
    15.4  | 
    47.4  | 
    45.4  | 
    31.8  | 
    28.8  | 
    21.5  | 
  
100  | 
    19.8  | 
    44.3  | 
    42.3  | 
    27.8  | 
    24.8  | 
    20.1  | 
  
155  | 
    25.2  | 
    41.5  | 
    39.5  | 
    23.9  | 
    20.9  | 
    18.8  | 
  
200  | 
    29.0  | 
    39.8  | 
    37.8  | 
    21.7  | 
    18.7  | 
    18.0  | 
  
250  | 
    32.8  | 
    38.3  | 
    36.3  | 
    19.8  | 
    16.8  | 
    17.3  | 
  
CONSTRUCTION PARAMETERS
| Cable Code | Conductor Diameter  | 
    Diameter Over Insulation  | 
    Pairs  | 
    Screen  | 
    Aprrox. Overall Diameter  | 
  
|---|---|---|---|---|---|
mm  | 
    mm  | 
    mm  | 
  |||
FTX-CAT6U/UTP4P23LH  | 
    0.56/0.57  | 
    1.02  | 
    4  | 
    Nil  | 
    6.0  | 
  
FTX-CAT6F/UTP4P23LH  | 
    0.57/0.58  | 
    1.02  | 
    4  | 
    Overall Aluminum Tape Screen  | 
    6.3  | 
  
FTX-CAT6SF/UTP4P23LH  | 
    0.57/0.58  | 
    1.02  | 
    4  | 
    Overall Aluminum Tape Screen& Copper Wire Braid  | 
    6.6  | 
  
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information