FIREGUARD Flame Retardant Cables | ![]() |
|
![]() |
Fire retardant cable(Fireguard)
600/1000V PVC Insulated, PVC Sheathed, Armoured Power Cables to BS 6346 (Single Core)
FGD300 1VVMAV-R (CU/PVC/PVC/AWA/PVC 600/1000V Class 2)
Application
600/1000V PVC Insulated, PVC Sheathed, Armoured Power Cables to BS 6346 (Single Core) are mainly
used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels,
hospitals, and high-rise buildings.
Standards
Basic design to to BS 6346
Approvals
TUV Certification (Z1 17 01 98200 004)
Fire Performance
Flame Retardance (Single Vertical Wire Test) | BS EN 50265-2-1 |
---|
Voltage Rating
600/1000V
Cable Construction
Conductor :Annealed copper wire, stranded according to BS 6360 class 2.
Insulation:PVC TI 1 according to BS 7655-3.1.
Bedding:PVC.
Armouring:Aluminium wire
Outer Sheath:PVC TM 1 according to BS 7655-4.1.
Outer Sheath Option:UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite
properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL
1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can
also be provided upon request.
Colour Code
Insulation Colour | Brown or blue |
---|---|
Sheath Colour |
Black, other colours can be offered upon request. |
Physical AND THERMAL PROPERTIES
Maximum temperature range during operation (PVC) | 70°C |
||||||
Maximum short circuit temperature (5 Seconds) |
160°C |
||||||
|
|||||||
Minimum bending radius |
|
||||||
|
Construction Parameters
Conductor | FGD300 1VVMAV-R |
||||||
---|---|---|---|---|---|---|---|
No. of Cores xCross Section |
Class of Conductor |
Nominal Insulation Thickness |
Nominal |
Nominal Armour Wire |
Nominal Sheath Thickness |
Approx. Overall |
Approx. Weight |
No.xmm2 |
|
mm |
mm |
mm |
mm |
mm |
kg/km |
1x50 |
2 |
1.4 |
0.8 |
1.25 |
1.5 |
19.1 |
820 |
1x70 |
2 |
1.4 |
0.8 |
1.25 |
1.6 |
21.1 |
1070 |
1x95 |
2 |
1.6 |
0.8 |
1.25 |
1.6 |
23.4 |
1390 |
1x120 |
2 |
1.6 |
1.0 |
1.6 |
1.7 |
26.3 |
1600 |
1x150 |
2 |
1.8 |
1.0 |
1.6 |
1.7 |
28.3 |
1900 |
1x185 |
2 |
2.0 |
1.0 |
1.6 |
1.8 |
30.8 |
2450 |
1x240 |
2 |
2.2 |
1.0 |
1.6 |
1.9 |
34.1 |
3100 |
1x300 |
2 |
2.4 |
1.0 |
1.6 |
1.9 |
37.0 |
3760 |
1x400 |
2 |
2.6 |
1.2 |
2.0 |
2.1 |
42.0 |
4850 |
1x500 |
2 |
2.8 |
1.2 |
2.0 |
2.1 |
45.6 |
5930 |
1x630 |
2 |
2.8 |
1.2 |
2.0 |
2.2 |
49.7 |
7390 |
1x800 |
2 |
2.8 |
1.4 |
2.5 |
2.4 |
55.8 |
9400 |
1x1000 |
2 |
3.0 |
1.4 |
2.5 |
2.5 |
61.0 |
11430 |
ELECTRICAL PROPERTIES
Conductor Operating Temperature | 70°C |
---|---|
Ambient Temperature |
30°C |
Current-Carrying Capacities (Amp) according to BS 7671: 2008 table 4D3A
Conductor cross-sectional area |
Reference |
Reference Method F (in free air or on a perforated cable tray, horizontal or vertical) |
|||||||||
Touching |
Touching |
Spaced by on cable diameter |
|||||||||
2 |
3 or 4 |
2 |
3 cables, |
3 cables |
2 cables, d.c. |
2 cables, single-phase |
3 or 4 |
||||
Horizontal |
Vertical |
Horizontal |
Vertical |
Horizontal |
Vertical |
||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
mm2 |
A |
A |
A |
A |
A |
A |
A |
A |
A |
A |
A |
50 |
193 |
179 |
205 |
189 |
181 |
229 |
216 |
229 |
217 |
230 |
212 |
70 |
245 |
225 |
259 |
238 |
231 |
294 |
279 |
287 |
272 |
286 |
263 |
95 |
296 |
269 |
313 |
285 |
280 |
357 |
340 |
349 |
332 |
338 |
313 |
120 |
342 |
309 |
360 |
327 |
324 |
415 |
396 |
401 |
383 |
385 |
357 |
150 |
393 |
352 |
413 |
373 |
373 |
479 |
458 |
449 |
429 |
436 |
405 |
185 |
447 |
399 |
469 |
422 |
425 |
548 |
525 |
511 |
489 |
490 |
456 |
240 |
525 |
465 |
550 |
492 |
501 |
648 |
622 |
593 |
568 |
566 |
528 |
300 |
594 |
515 |
624 |
547 |
567 |
748 |
719 |
668 |
640 |
616 |
578 |
400 |
687 |
575 |
723 |
618 |
657 |
885 |
851 |
737 |
707 |
674 |
632 |
500 |
763 |
622 |
805 |
673 |
731 |
1035 |
997 |
810 |
777 |
721 |
676 |
630 |
843 |
669 |
891 |
728 |
809 |
1218 |
1174 |
893 |
856 |
771 |
723 |
800 |
919 |
710 |
976 |
777 |
886 |
1441 |
1390 |
943 |
905 |
824 |
772 |
1000 |
975 |
737 |
1041 |
808 |
945 |
1685 |
1627 |
1008 |
967 |
872 |
816 |
Voltage Drop (Per Amp Per Meter) according to BS 7671: 2008 table 4D3B
Nominal Cross Section Area |
2 cables d.c. |
Ref. Methods C&F(clipped direct, on trays or in free air) |
||||||||||||||
2 cables, single-phase a.c. |
3 or 4 cables, three-phase a.c. |
|||||||||||||||
Touching |
Spaced* |
Trefoil and touching |
Flat and touching |
Flat and spaced* |
||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
||||||||||
mm2 |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
||||||||||
|
|
r |
x |
z |
r |
x |
z |
r |
x |
z |
r |
x |
z |
r |
x |
z |
50 |
0.93 |
0.93 |
0.22 |
0.95 |
0.92 |
0.30 |
0.97 |
0.80 |
0.19 |
0.82 |
0.79 |
0.26 |
0.84 |
0.79 |
0.34 |
0.86 |
70 |
0.63 |
0.64 |
0.21 |
0.68 |
0.66 |
0.29 |
0.72 |
0.55 |
0.18 |
0.58 |
0.57 |
0.25 |
0.62 |
0.59 |
0.32 |
0.68 |
95 |
0.46 |
0.48 |
0.20 |
0.52 |
0.51 |
0.28 |
0.58 |
0.42 |
0.175 |
0.45 |
0.44 |
0.25 |
0.50 |
0.47 |
0.31 |
0.57 |
120 |
0.36 |
0.39 |
0.195 |
0.43 |
0.42 |
0.28 |
0.50 |
0.33 |
0.170 |
0.37 |
0.36 |
0.24 |
0.43 |
0.40 |
0.30 |
0.50 |
150 |
0.29 |
0.31 |
0.190 |
0.37 |
0.34 |
0.27 |
0.44 |
0.27 |
0.165 |
0.32 |
0.30 |
0.24 |
0.38 |
0.34 |
0.30 |
0.45 |
185 |
0.23 |
0.26 |
0.190 |
0.32 |
0.29 |
0.27 |
0.39 |
0.22 |
0.160 |
0.27 |
0.25 |
0.23 |
0.34 |
0.29 |
0.29 |
0.41 |
240 |
0.18 |
0.20 |
0.180 |
0.27 |
0.23 |
0.26 |
0.35 |
0.175 |
0.160 |
0.23 |
0.20 |
0.23 |
0.30 |
0.24 |
0.28 |
0.37 |
300 |
0.145 |
0.160 |
0.180 |
0.24 |
0.19 |
0.26 |
0.32 |
0.140 |
0.155 |
0.21 |
0.165 |
0.22 |
0.28 |
0.20 |
0.28 |
0.34 |
400 |
0.105 |
0.140 |
0.175 |
0.22 |
0.18 |
0.24 |
0.30 |
0.12 |
0.130 |
0.195 |
0.160 |
0.21 |
0.26 |
0.21 |
0.25 |
0.32 |
500 |
0.086 |
0.120 |
0.170 |
0.21 |
0.165 |
0.23 |
0.29 |
0.105 |
0.145 |
0.18 |
0.145 |
0.20 |
0.25 |
0.19 |
0.24 |
0.30 |
630 |
0.068 |
0.105 |
0.165 |
0.195 |
0.150 |
0.22 |
0.27 |
0.091 |
0.145 |
0.17 |
0.135 |
0.195 |
0.23 |
0.175 |
0.22 |
0.28 |
800 |
0.053 |
0.095 |
0.160 |
0.185 |
0.145 |
0.21 |
0.25 |
0.082 |
0.140 |
0.160 |
0.125 |
0.180 |
0.22 |
0.170 |
0.195 |
0.26 |
1000 |
0.042 |
0.091 |
0.155 |
0.180 |
0.140 |
0.19 |
0.24 |
0.079 |
0.135 |
0.155 |
0.125 |
0.165 |
0.21 |
0.165 |
0.170 |
0.24 |
Note: *Spacings larger than one cable diameter will result in a large voltage drop.
r = conductor resistance at operating temperature
x = reactance
z = impedance