| FIREGUARD Flame Retardant Cables | |||
Fire retardant cable(Fireguard)
Flame Retardant CAT6 Data Cables
FGD-CAT6U/UTP4P23
FGD-CAT6F/UTP4P23
FGD-CAT6SF/UTP4P23
APPLICATION
Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT,
100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition,Flame Retardant CAT6 Data Cables can be
offered with copper wire braid armoured & flame retardant outer sheath, providing additional mechanically
protection still maintaining the flexibility of the cable.
STANDARDS
ISO/IEC 11801 EN 50173 ANSI/TIA/EIA 568

FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) : BS EN 60332-1-2
CABLE CONSTRUCTION

Conductor : 23AWG solid bare copper.
Insulation : PE.
Twinning : Two coloured insulated conductors twisted together to form a pair.
Outer Sheath : Thermoplastic PVC compound.
Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite
properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL
1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can
also be provided upon request.
Cat6F/UTP : These cables have collective shielding of Aluminium/polyester tape with drain wire.
Cat6SF/UTP : These cables have double collective shielding of Aluminium/polyester tape & copper wire braid with
drain wire.
PHYSICAL AND THERMAL PROPERTIES
Temperature range : -30°C - +75°C
Minimum bending radius during installation (mobile state) : 8 x Overall Diameter
Minimum bending radius during operation (fixed state) : 4 x Overall Diameter
ELECTRICAL PROPERTIES
| AWG |
|
23 |
|---|---|---|
Nominal Conductor Diameter |
mm |
0.56/0.57/0.58 |
Maximum DC Resistance@20°C |
Ω/100m |
9.38 |
Maximum DCR Unbalance |
% |
3 |
Maximum Mutual Capacitance |
pF/m |
5.8 |
Maximum Capacitance Unbalance |
pF/100m |
30 |
Characteristic Impedance@1-100MHz |
Ω |
100±15 |
Maximum Propagation Delay Skew |
ns/100m |
18 |
TRANSMISSION PROPERTIES
| FREQ | Attenuation |
NEXT |
PSNEXT |
ELFEXT |
PSELFEXT |
RL |
|---|---|---|---|---|---|---|
MHz |
dB/100m |
dB |
dB |
dB/100m |
dB/100m |
dB |
0.772 |
1.8 |
76.0 |
74. |
70.0 |
67.0 |
— |
1 |
2.0 |
74.3 |
72.3 |
67.8 |
64.8 |
20.0 |
4 |
3.8 |
65.3 |
63.3 |
55.7 |
52.7 |
23.0 |
8 |
5.3 |
60.8 |
58.8 |
49.7 |
46.7 |
24.5 |
10 |
6.0 |
59.3 |
57.3 |
47.8 |
44.8 |
25.0 |
16 |
7.6 |
56.3 |
54.3 |
43.7 |
40.7 |
25.0 |
20 |
8.5 |
54.8 |
52.8 |
41.7 |
38.7 |
25.0 |
25 |
9.5 |
53.3 |
51.3 |
39.8 |
36.8 |
24.3 |
31.25 |
10.7 |
51.9 |
49.9 |
37.9 |
34.9 |
23.6 |
62.5 |
15.4 |
47.4 |
45.4 |
31.8 |
28.8 |
21.5 |
100 |
19.8 |
44.3 |
42.3 |
27.8 |
24.8 |
20.1 |
155 |
25.2 |
41.5 |
39.5 |
23.9 |
20.9 |
18.8 |
200 |
29.0 |
39.8 |
37.8 |
21.7 |
18.7 |
18.0 |
250 |
32.8 |
38.3 |
36.3 |
19.8 |
16.8 |
17.3 |
CONSTRUCTION PARAMETERS
| Cable Code | Conductor Diameter |
Diameter Over Insulation |
Pairs |
Screen |
Approx. Overall Diameter |
|---|---|---|---|---|---|
mm |
mm |
mm |
|||
FGD-CAT6U/UTP4P23 |
0.56/0.57 |
1.02 |
4 |
Nil |
6.0 |
FGD-CAT6F/UTP4P23 |
0.57/0.58 |
1.02 |
4 |
Overall Aluminum Tape Screen |
6.3 |
FGD-CAT6SF/UTP4P23 |
0.57/0.58 |
1.02 |
4 |
Overall Aluminum Tape Screen& Copper Wire Braid |
6.6 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information