CAN Bus Cables Application: These cables is a variable field bus system.  Automation Industries, such as the textile or construction machine industry are commonly use this type of cables. CAN Bus 0.22mm2 Flexible Cables CAN Bus 0.34mm2 Flexible Cables CAN Bus 0.50mm2 Flexible Cables CAN Bus 0.25mm2 Drag Chain Cables   CAN Bus 0.22mm2 Flexible Cables Conductor: Bare Copper (AWG 24/7)  Insulation: Cell PE  Conductor Colour: White, Brown / White, Brown, Green-Yellow  Stranding: Double Conductor (1 pair 2 core) / Star quad (4 pair single core)  Shielding: Polyester foil over stranded bundle  Total Shielding: Tinned Copper Braid  Sheath/Jacket: PVC  Colour: Violet  Outer Cable Diameter: 5.4 mm ± 0.2 mm (1 pair 2 core) / 6.9 mm ± 0.2 mm Nominal Voltage: 30 V Test Voltage: 1.5 kV   Operating temperature: - 40 °C to +70°C Standards: Profibus acc. to DIN 19245 T3 and EN 50170  UL Style: UL Style 2571  
                        
                          | Size (Type) | Characteristic Impedance | Conductor Resistance  | Insulation Resistance  | Mutual Capacitance  | Min. Bending Radius  | Caloric Load, approx. value | Weight |  
                          | 1 X 2 X 0.22mm2 | 120 Ohm ± 10% | 87.0 Ohm/km | 1.0 GOhm x km Min.  | 58.0 nF/km Nom.  | 81.0 mm  | 0.57 MJ/m | Approx. 35.0 kg/km  |  
                          | 4 X 1 X 0.22mm2  | 120 Ohm ± 10% | 87.0 Ohm/km | 1.0 GOhm x km Min.  | 58.0 nF/km Nom. | 107.0 mm  | 1.23 MJ/m | Approx. 60.0 kg/km |    CAN Bus 0.34mm2 Flexible Cables Conductor: Bare Copper (AWG 24/7)  Insulation: Cell PE  Conductor Colour: White, Brown / White, Brown, Green-Yellow  Stranding: Double Conductor (1 pair 2 core) / Star quad (4 pair single core)  Shielding: Polyester foil over stranded bundle  Total Shielding: Tinned Copper Braid  Sheath/Jacket: PVC  Colour: Violet  Outer Cable Diameter: 6.5 mm ± 0.2 mm (1 pair 2 core) / 8.0 mm ± 0.2 mm Nominal Voltage: 30 V Test Voltage: 2.0 kV  Operating temperature: - 25 °C to +70°C Standards: Profibus acc. to DIN 19245 T3 and EN 50170  UL Style: UL Style 2571  
                        
                          | Size (Type) | Characteristic Impedance | Conductor Resistance  | Insulation Resistance  | Mutual Capacitance  | Min. Bending Radius  | Caloric Load, approx. value | Weight |  
                          | 1 X 2 X 0.34mm2 | 120 Ohm ± 10% | 57.5 Ohm/km | 5.0 GOhm x km Min.  | 40.0 nF/km Nom.  | 98.0 mm  | 1.11 MJ/m | Approx. 54.0 kg/km  |  
                          | 4 X 1 X 0.34mm2  | 120 Ohm ± 10% | 57.5 Ohm/km | 5.0 GOhm x km Min.  | 40.0 nF/km Nom. | 120.0 mm  | 1.18 MJ/m | Approx. 77.0 kg/km |    CAN Bus 0.50mm2 Flexible Cables Conductor: Bare Copper (AWG 20/7)  Insulation: Foam skin PE Conductor Colour: White, Brown / White, Brown, Green-Yellow  Stranding: Double Conductor (1 pair 2 core) / Star quad (4 pair single core)  Shielding: Polyester foil over stranded bundle  Total Shielding: Tinned Copper Braid  Sheath/Jacket: PVC  Colour: Violet  Outer Cable Diameter: 7.0 mm ± 0.2 mm (1 pair 2 core) / 8.5 mm ± 0.2 mm Test Voltage: 1.5 kV  Operating temperature: - 40 °C to +70°C Standards: Profibus acc. to DIN 19245 T3 and EN 50170  UL Style: UL Style 2571  
                        
                          | Size (Type) | Characteristic Impedance | Conductor Resistance  | Insulation Resistance  | Mutual Capacitance  | Min. Bending Radius  | Caloric Load, approx. value | Weight |  
                          | 1 X 2 X 0.50mm2 | 120 Ohm ± 10% | 37.0 Ohm/km | 1.0 GOhm x km Min.  | 50.0 nF/km Nom.  | 105.0 mm  | 1.09 MJ/m | Approx. 69.0 kg/km  |  
                          | 4 X 1 X 0.50mm2  | 120 Ohm ± 10% | 37.0 Ohm/km | 1.0 GOhm x km Min.  | 50.0 nF/km Nom. | 128.0 mm  | 1.64 MJ/m | Approx. 100.0 kg/km |    CAN Bus 0.25mm2 Drag Chain Cable Conductor: Bare Copper (AWG 24/19)  Insulation: PE Conductor Colour: White, Brown / White, Brown, Green-Yellow  Stranding: Double Conductor (1 pair 2 core) / Star quad (4 pair single core)  Shielding: Polyester foil over stranded bundle  Total Shielding: Tinned Copper Braid  Sheath/Jacket: PUR Colour: Violet  Outer Cable Diameter: 6.2 mm ± 0.3 mm (1 pair 2 core) / 6.5 mm ± 0.3 mm Test Voltage: 1.5 kV  Operating temperature: - 20°C to +70°C Standards: Profibus acc. to DIN 19245 T3 and EN 50170  
                        
                          | Size (Type) | Characteristic Impedance | Conductor Resistance  | Insulation Resistance  | Mutual Capacitance  | Min. Bending Radius  | Caloric Load, approx. value | Weight |  
                          | 1 X 2 X 0.25mm2 | 120 Ohm ± 10% | 85.0 Ohm/km | 1.0 GOhm x km Min.  | 50.0 nF/km Nom.  | 90.0 mm  | 0.80 MJ/m | Approx. 40.0 kg/km  |  
                          | 4 X 1 X 0.25mm2  | 120 Ohm ± 10% | 85.0 Ohm/km | 1.0 GOhm x km Min.  | 50.0 nF/km Nom. | 95.0 mm  | 0.94 MJ/m | Approx. 45.0 kg/km |    |