|  Bus Cables
ASI  Cables Application: The ASI is the field bus system that transmits both data and power in 
one single cable. With fast contacting in penetration technique, it can largely reduce the possibility 
of errors in cabling. Different jacket can provide protection against  oils, grease, and 
refrigerant lubricants. ASI EPDM Cables ASI PUR Cables ASI PVC Cables   ASI EPDM Cables   Conductor: Tinned Copper
                       Insulation: Rubber Compound Conductor Colour: Blue, Brown Sheath/Jacket: EPDM Colour: Yellow / Black Operating temperature: - 40 °C to  +85 °C Standards: ASI Standard 
                        
                          | Size (Type) | Conductor Resistance  | Insulation Resistance  | Nominal Voltage  | Testing Voltage  | Min. Bending Radius  | Caloric Load, approx. value | Weight |  
                          | 2 X 1.5mm2 (Yellow)   | 13.7 Ohm/km  | 1.00 GOhm x km Min.  | 32 V | 1.0 kV @ 15 min.  | 30.0 mm | 0.96 MJ/m | Approx. 70.0 kg/km  |  
                          | 2 X 1.5mm2 (Black) | 13.7 Ohm/km | 1.00 GOhm x km Min.  | 48 V | 1.0 kV @ 15 min.  | 30.0 mm  | 0.96 MJ/m | Approx. 70.0 kg/km |    ASI PUR Cables Conductor: Tinned Copper  Insulation: Rubber Compound Conductor Colour: Blue, Brown Sheath/Jacket: PUR  Colour: Yellow / Black Operating temperature: - 40 °C to  +85 °C Standards: ASI Standard 
                        
                          | Size (Type) | Conductor Resistance  | Insulation Resistance  | Nominal Voltage  | Testing Voltage  | Min. Bending Radius  | Caloric Load, approx. value | Weight |  
                          | 2 X 1.5mm2 (Yellow)  | 13.7 Ohm/km  | 1.00 GOhm x km Min.  | 32 V | 1.0 kV @ 15 min.  | 30.0 mm | 0.96 MJ/m | Approx. 64.0 kg/km  |  
                          | 2 X 1.5mm2 (Black) | 13.7 Ohm/km | 1.00 GOhm x km Min.  | 48 V | 1.0 kV @ 15 min.  | 30.0 mm  | 0.96 MJ/m | Approx. 64.0 kg/km |    ASI PVC Cable Conductor: Tinned Copper  Insulation: TPE  Conductor Colour: Blue, Brown Sheath/Jacket: PVC Colour: Yellow / Black Operating temperature: - 40 °C to +105 °C Standards: ASI Standard UL Style: CMG 90°C or CL2 CSA Standard: CSA FT4 
                        
                          | Size (Type) | Conductor Resistance  | Insulation Resistance  | Nominal Voltage  | Testing Voltage  | Min. Bending Radius  | Caloric Load, approx. value | Weight |  
                          | 2 X 1.5mm2 (Yellow)  | 13.7 Ohm/km  | 1.00 GOhm x km Min.  | 32 V | 1.0 kV @ 15 min.  | 24.0 mm | 0.66 MJ/m | Approx. 70.0 kg/km  |  
                          | 2 X 1.5mm2 (Black) | 13.7 Ohm/km | 1.00 GOhm x km Min.  | 48 V | 1.0 kV @ 15 min.  | 24.0 mm  | 0.65 MJ/m | Approx. 70.0 kg/km |    |