Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial 

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Hoop-Up Wire

Hoop-Up Wire

Application

For general purpose internal wiring of electronic and electrical equipment, where exposed to oil at a temperature not exceeding 60°C or 80°C.

Descriptions

Solid or stranded, tinned or bare copper conductor, 28-10 AWG

Color coded PVC insulation

Rated Temperature: 105°C

Rate Voltage: 600V

Uniform thickness of wire to ensure easy stripping and cutting

Passes UL VW-1 & CSA FT1 vertical flame test

Resistant to acids, oils, alkalies, moisture and fungus

Specification:

Conductor

type

Conductor

Insulation

Max

Resistance

At20°C

Min Insulation

Resistance

At20°C

Dielectric

Strength

AC 1min

Spec

No.

Nom.

Dia.

Nom.

Thick.

Nom.

Dia

AWG

mm

mm

mm

mm

Ω /km

MΩ . km

V

 

 

 

 

 

Stranded

Conductor

30

7/0.10

0.30

0.79

1.88

354.24

 

 

 

 

 

 

15

 

 

 

 

 

 

 

1500

28

7/0.127

0.38

0.79

1.96

223.75

26

7/0.127

0.48

0.79

2.06

139.73

24

11/0.16

0.61

0.79

2.19

93.3

22

17/0.16

0.76

0.79

2.34

55.0

20

26/0.16

0.94

0.79

2.52

34.6

18

41/0.16

1.18

0.79

2.76

21.8

16

26/0.254

1.49

0.79

3.07

13.7

14

41/0.254

1.88

0.79

3.46

8.62

12

65/0.254

2.37

0.79

3.95

5.43

10

105/0.254

3.40

0.79

4.98

3.41

49/0.37

3.38

0.79

4.96

3.41

 

 

Solid

Conductor

28

1/0.32

0.32

0.79

1.90

227.39

 

 

 

15

 

 

 

1500

26

1/0.404

0.404

0.79

1.98

142.79

24

1/0.511

0.511

0.79

2.09

89.39

22

1/0813

0.643

0.79

2.22

54.3

20

1/1.29

0.813

0.79

2.39

33.9

18

1/1.024

1.024

0.79

2.60

21.4

16

1/1.29

1.29

0.79

2.87

13.5