Energie Kabel 
                      
                        
                          XLPE Insulated, PVC/LSOH Bedding, Wire Armoured, PVC/LSOH Oversheathed Power Cable  | 
                         
                        
                          Voltage Rating  
        600/1000V, 1800/3000V , 3800/6600V   | 
                         
                       
                      
                        
                          Construction   | 
                         
                        
                          Dirigenten :   | 
                          Plain annealed stranded copper conductor   | 
                         
                        
                          Isolatie :   | 
                          XLPE compound   | 
                         
                        
                          Filler (where applicable) :   | 
                          Polypropylene yarn   | 
                         
                        
                          Binder Tape (where applicable) :   | 
                          Polyester (mylar) tape   | 
                         
                        
                          Bedding (for armoured cable) :   | 
                          PVC/LSOH compound   | 
                         
                        
                          Armouring (for armoured cable) :   | 
                          Aluminium wire (single core) or Galvanized steel wires (multicore)   | 
                         
                        
                          Condooms :   | 
                          PVC/LSOH compound   | 
                         
                       
                        
                      
                        
                          Kleur van de identificatie  | 
                         
                        
                          Isolatie  | 
                          1-Core :   | 
                          Natural  | 
                         
                        
                          2-Core :   | 
                          Red and Black  | 
                         
                        
                          3-Core :   | 
                          Red, Yellow and Blue  | 
                         
                        
                          4-Core :   | 
                          Red, Yellow, Blue and Black   | 
                         
                        
                          Condooms  | 
                          Black, Grey or White   | 
                         
                       
                        
                      
                        
                          Test Standards   | 
                         
                        
                          Design Standard   | 
                          Materials Test   | 
                          Flame Retardancy Test   | 
                          Test on halogen content  
                              Acid Gas Evolved   | 
                          Smoke Density Test (BS6724)   | 
                         
                        
                          BS 5467   | 
                          BS 443   | 
                          BS 4066 PART 1   | 
                          BS6425   | 
                          BS 7622   | 
                         
                        
                          BS 6724   | 
                          BS 2627   | 
                          BS 4066 PART 3   | 
                           IEC 754-1   | 
                          IEC 61034   | 
                         
                        
                          BS 7211   | 
                          BS 7655   | 
                          IEC 60332-1   | 
                          -  | 
                          -  | 
                         
                        
                          IEC 60228   | 
                          IEC 60811   | 
                          IEC 60332-3   | 
                          -  | 
                          -  | 
                         
                        
                          IEC 60502-1   | 
                          -  | 
                          -  | 
                          -  | 
                          -  | 
                         
                        
                          BS6622  | 
                          -  | 
                          -  | 
                          -  | 
                          -  | 
                         
                       
                        
                      
                        
                          IEC Standard  | 
                         
                        
                          600/1000V Single Core, XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502   | 
                         
                        
                          600/1000V Two Core, XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502   | 
                         
                        
                          600/1000V Three Core, XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502   | 
                         
                        
                          600/1000V Four Core , XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502   | 
                         
                        
                          600/1000V Multicore, XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502   | 
                         
                        
                             | 
                         
                        
                          1800/3000V Single Core, XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502   | 
                         
                        
                          1800/3000V Three Core, XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502   | 
                         
                        
                          BS Standard  | 
                         
                        
                          600/1000V Single Core, XLPE Insulated, PVC Sheathed, Armoured to BS 5467   | 
                         
                        
                          600/1000V Two Core, XLPE Insulated, PVC Sheathed, Armoured to BS 5467   | 
                         
                        
                          600/1000V Three Core, XLPE Insulated, PVC Sheathed, Armoured to BS 5467  | 
                         
                        
                          600/1000V Four Core, XLPE Insulated, PVC Sheathed, Armoured to BS 5467   | 
                         
                        
                          600/1000V Four Core ( reduced neutral ) , XLPE Insulated, PVC Sheathed, Armoured to BS 5467   | 
                         
                        
                          600/1000V Five Core, XLPE Insulated, PVC Sheathed, Armoured to BS 5467   | 
                         
                        
                          600/1000V Single Core, XLPE Insulated, LSOH Sheathed, Armoured to BS 6724   | 
                         
                        
                          600/1000V Two Core, XLPE Insulated, LSOH Sheathed, Armoured to BS 6724   | 
                         
                        
                          600/1000V Three Core, XLPE Insulated, LSOH Sheathed, Armoured to BS 6724   | 
                         
                        
                          600/1000V Four Core, XLPE Insulated, LSOH Sheathed, Armoured to BS 6724   | 
                         
                        
                          600/1000V Four Core ( reduced neutral ) , XLPE Insulated, LSOH Sheathed, Armoured to BS 6724   | 
                         
                        
                          600/1000V Five Core, XLPE Insulated, LSOH Sheathed, Armoured to BS6724   | 
                         
                        
                          600/1000V Multicore, XLPE Insulated, LSOH Sheathed, Armoured to BS 6724   | 
                         
                        
                             | 
                         
                        
                          1900/3300V Single Core, XLPE Insulated, PVC Sheathed, Armoured to BS 5467   | 
                         
                        
                          1900/3300V Three Core, XLPE Insulated, PVC Sheathed, Armoured to BS 5467   | 
                         
                        
                          1900/3300V Single Core, XLPE Insulated, LSOH Sheathed, Armoured to BS 6724   | 
                         
                        
                          1900/3300V Three Core, XLPE Insulated, LSOH Sheathed, Armoured to BS 6724   | 
                         
                        
                          3800/6600V Three Core, XLPE Insulated, PVC Sheathed, Armoured to BS 6622   | 
                         
                        
                          3800/6600V Four Core, XLPE Insulated, PVC Sheathed, Armoured to BS 6622   | 
                         
                        
                          ICEA Standard  | 
                         
                        
                          0-600V 100/133% Insulation Level Single Core Unarmoured PVC type to ICEA S-66-524   | 
                         
                        
                          0-600V 100/133% Insulation Level Three Core Unarmoured PVC Type to ICEA S-66-524   | 
                         
                       
                        
                        
                      |