| Fiber Optic Cables | ||||
Mechanical & Environmental Properties for Single Mode Fiber
| Testing Parameters | EIA/TIA-455 FOTP Number | IEC-794-1 Test Method | EN 187000Test Method | Maximum Increased loss |
|---|---|---|---|---|
| Tensile Load & Bending | 33 | E1 | 501 | <0.05dB (90%); <0.15dB (100%) |
| Low & HighTemperature Bend | 37 | E11 | <0.05dB (90%); <0.15dB (100%) | |
| Compression loading (Crush) | 41 | E3 | 504 | <0.05dB (90%); <0.15dB (100%) 440N/km(250lb/in) load |
| Impact Resistance | 25 | E4 | 505 | <0.05dB (90%); <0.15dB (100%) |
| Twist (Torson) | 85 | E7 | 508 | <0.05dB (90%); <0.15dB (100%) |
| Cyclic Flexing(Repeated Bending) | 104 | E6 | 509 | <0.05dB (90%); <0.15dB (100%) |
| External freezing | 98 | F6 | <0.05dB (90%); <0.15dB (100%) | |
| Temperature Cycling | 3 | F1 | 601 | <0.05dB (90%); <0.15dB (100%) |
| Fiber Stripability | 178 | B6 | <8.9N(2lbf) on unaged and aged fi ber; >1.3N(0.3lbf) on unaged and aged fi ber | |
| Cable Aging | 82 | F5 | <0.1dB (90%); <0.25dB (100%) | |
| Water Penetration | 82 | F5 | No flow after 24 hours from 1 meter length of cable | |
| Compound Flow (Drip) | 81 | E14 | 80 C 24 hrs duration, no drip |
Mechanical & Environmental Properties for Multi Mode Fiber
| Testing Parameters | EIA/TIA-455 FOTP Number | IEC-794-1 Test Method | EN 187000 Test | MethodMaximum Increased loss |
|---|---|---|---|---|
| Tensile Load & Bending | 33 | E1 | 501 | <0.2dB |
| Low & HighTemperature Bend | 37 | E11 | <0.4dB | |
| Compression loading (Crush) | 41 | E3 | 504 | <0.2dB 440N/km(250lb/in) load |
| Cyclic Impact | 25 | E4 | 505 | <0.4dB |
| Twist (Torsion) | 85 | E7 | 508 | <0.2dB |
| Cyclic Flexing(Repeated Bending) | 104 | E6 | 509 | <0.2dB |
| External freezing | 98 | F6 | <0.2dB | |
| Temperature Cycling | 3 | F1 | 601 | <0.05dB (90%); <0.15dB (100%) |
| Fiber Stripability | 178 | B6 | <13.4N(3lbf) on unaged fi ber | |
| Cable Aging | 82 | F5 | <0.1dB (90%); <0.25dB (100%) | |
| Water Penetration | 82 | F5 | No flow after 24 hours from 1 meter length of cable | |
| Compound Flow (Drip) | 81 | E14 | 80 C 24 hrs duration, no drip |