FTN Screening Conductor Cables
                        Application
The cables are designed to be used for the purpose of screening telecommunication cables from electrical
interference.
Standards
NR/PS/TEL/31102(BR1817)
BS 6485
Construction

Conductors
Single core stranded aluminium to BS 215PT1.
Insulation
PVC type 16 to BS 6485 or LSZH.
Electrical Characteristics at 20℃
| Nominal Conductor Cross Section | mm² | 150 | 250 | 
|---|---|---|---|
| Maximum DC Conductor Resistance | Ω/km | 0.1825 | 0.1083 | 
Mechanical and Thermal Properties
Minimum Bending Radius: 9×OD
Temperature Range:0℃ to +70℃ (during operation);
0℃ to +55℃ (during installation)
Dimensions And Weight
| Cable Code | No. of cores& Nominal
                              Conductor Cross Sectional Area No.×mm²  | 
                            No. & Nominal
                              Diameter of Strands No/mm  | 
                            Nominal
                              Thickness of Insulation mm  | 
                            Nominal
                              Overall Diameter mm  | 
                            Nominal
                              Weight kg/km  | 
                          
|---|---|---|---|---|---|
| RF31102-H07V-U-450/750V-1G150AL | 1×150 | 19/3.25 | 1.6 | 19.45 | 629 | 
| RF31102-H07V-U-450/750V-1G250AL | 1×250 | 19/4.22 | 1.6 | 24.30 | 995 | 
U is changed to K if the stranding class is changed from class 2 to class 5