| Coaxial Cables | ||||||||||||
CK 059/F2:RG59BX + 2 x 0.5mm2
Construction
| Inner conductor1 | Copper covered steel(CCS) | 0.58mm |
|---|---|---|
| Dielectric | LowdensityPE | Φ3.70±0.10mm |
| Outer conductor(shield) | Plain copper | 180x0.10mm |
| Shield coverage | 94% | |
| Sheath | PVC | Φ6.20±0.10mm |
| Inner conductor2 | Plain copper | 2x0.50mm2 |
| Insulated cores2 | PVC | 2xΦ1.50±0.10mm |
| Overall sheath | Φ10.30±0.30mm |
Electrical Mechanical Characteristics
Impedance :75±5Ohm
Nominal capacitance :67pF/m
Velocity of propagation :66%
Insulation resistance :>2000Mohm.Km
Inner conductor resistance :158Ohm/Km
Outer conductor resistance :11Ohm/Km
Operating temperature range :-25°C-+80°C
Cores resistance :39Ohm/Km
Test/Operatig Voltage(max) :1.2KV/0.25KV
Copper weight :24.5Kg/Km
Cable weight(approx.) :142.8Kg/Km
Screening effectiveness :>55dB
Attenuation
| Frequency(MHz) | Attenuation(dB/100m) | Attenuation(dB/100ft) |
|---|---|---|
| 50 | 7.4 | 2.26 |
| 100 | 10.7 | 3.26 |
| 200 | 15.7 | 4.79 |
| 400 | 22.7 | 6.92 |
| 500 | 25.7 | 7.84 |
| 600 | 28.7 | 8.75 |
| 860 | 34.8 | 10.61 |
| 1000 | 38 | 11.59 |
Return Loss
| 30-300MHz | >31dB |
|---|---|
| 300-600MHz | >28dB |
| 600-900MHz | >24dB |