Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Bus Cavi

Bus Cavi

E-Bus Cables

Applicazione: These cables are used for the transmission of bus signals in buildings, where intelligent system are used. The EIB bus can be used to control lighting, blinds, heating, ventilation, indicator boards, etc. This cables can maintain perfect communicationaccording to EIB regulations (European installation bus).

2 Pairs 4 Core FRNC & PVC E-Bus Cables

2 Pairs 4 Core PE E-Bus Cables

4 Pairs 4 Core PVC E-Bus Cables

 

2 Pairs 4 Core FRNC & PVC E-Bus Cables

Conduttore: Bare Copper

Isolamento: PVC

Core identification: White, Yellow, Red, Black

Stranding: Star quad

Shielding: Polyester foil over stranded bundle

Total Shielding: Polyester foil, aluminum-lined

Sheath/Jacket: PVC

Colour: Blue, Green

Conduttore di Drenaggio: Yes

Outer Cable Diameter: 6.6 mm ± 0.3 mm

temperatura operativa: - 30 °C to +70°C

Standards: EIB Standard

Size (Type)

Characteristic Impedance
Conductor Resistance
Insulation Resistance
Mutual Capacitance
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 2 X 0.8mm2 (Blue)

100 Ohm
73.2 Ohm/km
0.10 GOhm x km Min.
100.0 nF/km Nom.
95.0 mm
0.90 MJ/m
Approx. 54.0 kg/km

2 X 2 X 0.8mm2 (Green)

100 Ohm
73.2 Ohm/km
0.10 GOhm x km Min.
100.0 nF/km Nom.
95.0 mm
0.90 MJ/m
Approx. 54.0 kg/km

 

2 Pairs 4 Core PE E-Bus Cables

Conductor: Bare Copper

Insulation: PE

Conductor Colour: White, Yellow, Red, Black

Stranding: Star quad

Shielding: Polyester foil over stranded bundle

Total Shielding: Polyester foil, aluminum-lined

Sheath/Jacket: FRNC

Colour: Blue

Drain Wire: Yes

Outer Cable Diameter: 6.6 mm ± 0.3 mm

Operating temperature: - 30 °C to +70°C

Standards: EIB Standard

Size (Type)

Characteristic Impedance
Conductor Resistance
Insulation Resistance
Mutual Capacitance
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 2 X 0.8mm2

100 Ohm
73.2 Ohm/km
0.10 GOhm x km Min.
100.0 nF/km Nom.
95.0 mm
0.58 MJ/m
Approx. 54.0 kg/km

 

4 Pairs 4 Core PVC E-Bus Cables

Conductor: Bare Copper

Insulation: PVC

Conductor Colour: White, Yellow, Red, Greed, Blue, Brown, White, White

Stranding: Double Conductor

Shielding: Polyester foil over stranded bundle

Total Shielding: Polyester foil, aluminum-lined

Sheath/Jacket: PVC

Colour: Blue

Drain Wire: Yes

Outer Cable Diameter: 8.3 mm ± 0.4 mm

Operating temperature: - 30 °C to +70°C

Standards: EIB Standard

Size (Type)

Characteristic Impedance
Conductor Resistance
Insulation Resistance
Mutual Capacitance
Min. Bending Radius
Caloric Load, approx. value
Weight

4 X 2 X 0.8mm2

100 Ohm
73.2 Ohm/km
0.10 GOhm x km Min.
100.0 nF/km Nom.
120.0 mm
1.37 MJ/m
Approx. 92.0 kg/km