HOMEPRODUCTS MARINE CABLES

 

UKOOA TYPE YC 600/1000V Fire Resistant

 

Application:

Marine cables are designed for fixed installation for power, control and lighting in both and safe areas, emergency and critical offshore applications where cable protection is required.

Standards:

BS 6883/BS 7917/UKOOA

IEC 60331-21 

IEC 60332-3-22 CAT. A

IEC 60332-1

IEC 60754-1 & IEC 60754-2

IEC 61034-1 & IEC 61034-2

Construction:

Conductors:Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS 6360/IEC 60228.

Fire Protection :Mica glass tape 

Insulation:EPR complying with BS7655 GP4 

Bedding:EVA - SW4 compound complying with BS 7655. 

Armour :Tinned Phosphor Bronze Wire Braid to BS2873-PB102 (now BS EN 12166) 

Outer Sheath :EVA - SW4 compound complying with BS 7655

Dimensions and Weight:

Construction
No. of cores×Cross section
Nominal Insulation Thickness
Nominal Thickness of Inner Sheath 
Nominal Thickness of Outer Sheath 
Nominal Overall Diameter
Approx. Weight
mm² mm mm mm mm kg/km
1×1.0 0.8 1.1 1.2 10.0 158
1×1.5 0.8 1.1 1.2 10.3 179
1×2.5 0.8 1.1 1.2 10.7 200
1×4 1.0 1.1 1.2 11.8 273
1×6 1.0 1.1 1.2 12.3 357
1×10 1.0 1.1 1.2 13.5 410
1×16 1.0 1.1 1.2 14.7 504
1×25 1.2 1.1 1.2 17.3 593
1×35 1.2 1.1 1.3 18.4 777
1×50 1.4 1.1 1.4 20.2 987
1×70 1.4 1.1 1.4 22.4 1333
1×95 1.6 1.1 1.5 25.0 1575
1×120 1.6 1.2 1.6 27.1 1838
1×150 1.8 1.2 1.6 29.5 2310
1×185 2.0 1.2 1.7 33.1 2835
1×240 2.2 1.2 1.8 36.5 3570
1×300 2.4 1.2 1.9 40.0 4410
1×400 2.6 1.2 1.9 44.2 5985
1×500 2.8 1.2 1.9 48.6 7560
1×630 2.8 1.2 1.9 52.8 9282