HOMEPRODUCTS MARINE CABLES

 

UKOOA TYPE KG / TYPE KJ 150/250V Flame Retardant

 

Application:

Marine cables are designed for fixed installation for control and lighting in both and safe areas, emergency and critical offshore applications where cable protection is required.

Standards:

BS 6883/BS 7917/UKOOA

IEC 60332-3-22 CAT. A

IEC 60332-1

IEC 60754-1 & IEC 60754-2

IEC 61034-1 & IEC 61034-2

Construction:

Conductors:Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS 6360/IEC 60228.

Insulation:EPR complying with BS7655 GP4 

Drain Wire: Tinned copper drain wire

Collective Screen:Aluminium mylar tape screen

Bedding:EVA - SW4 compound complying with BS 7655 

Armour :Galvanised steel wire braid to BS 6883 

Outer Sheath :EVA - SW4 compound complying with BS 7655 (TYPE KG: Blue; TYPE KJ: Grey).

Dimensions and Weight:

Construction
No. of cores×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Thickness of Inner Sheath 
mm
Nominal Thickness of Outer Sheath 
mm
Nominal Overall Diameter
mm
Approx. Weight
kg/km
1×2×0.75 0.8 1.2 1.25 12.9 200
3×2×0.75 0.8 1.2 1.4 17.9 468
7×2×0.75 0.8 1.4 1.7 22.4 706
12×2×0.75 0.8 1.6 1.7 28.0 1030
20×2×0.75 0.8 1.8 2.0 35.2 1662
1×3×0.75 0.8 1.0 1.25 13.5 285
3×3×0.75 0.8 1.3 1.2 20.4 680
7×3×0.75 0.8 1.5 1.4 26.0 1325
12×3×0.75 0.8 1.7 1.7 34.6 2106
1×2×1.0 0.8 1.0 1.0 13.4 180
1×3×1.0 0.8 1.1 1.1 14.0 300
1×4×1.0 0.8 1.1 1.2 15.0 180
1×2×1.5 0.8 1.1 1.2 13.5 297
3×2×1.5 0.8 1.3 1.4 19.8 593
7×2×1.5 0.8 1.4 1.6 25.0 929
12×2×1.5 0.8 1.7 1.9 32.6 1510
20×2×1.5 0.8 1.9 2.1 39.9 2287
1×3×1.5 0.8 1.1 1.2 14.0 304
3×3×1.5 0.8 1.3 1.5 23.7 760
7×3×1.5 0.8 1.5 1.7 30.5 1262
12×3×1.5 0.8 1.8 2.0 40.7 2148
1×2×2.5 0.8 1.1 1.2 15.1 320