HOMEPRODUCTS MARINE CABLES

 

UKOOA TYPE JG / TYPE JJ 150/250V Flame Retardant

 

 

Application:

UKOOA TYPE JG / TYPE JJ 150/250V Flame Retardant cables are designed for fixed installation for control and lighting in both and safe areas, emergency and critical offshore applications where cable protection is required.

Standards :

BS 6883/BS 7917/UKOOA

IEC 60332-3-22 CAT. A

IEC 60332-1

IEC 60754-1 & IEC 60754-2

IEC 61034-1 & IEC 61034-2

Construction :

Conductors :Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS 6360/IEC 60228.

Insulation:EPR complying with BS7655 GP4 

Drain Wire:Tinned copper drain wire 

Collective Screen:Aluminium mylar tape screen

Bedding:CSP – SW2 compound complying with BS 7655 

Armour:Galvanised steel wire braid to BS 6883 

Outer Sheath :CSP – SW2 compound complying with BS 7655 (TYPE JG: Blue; TYPE JJ: Grey).

Dimensions and Weight :


Construction No. of cores×Cross section(mm²)
Nominal Insulation Thickness mm Nominal Thickness of Inner Sheath mm Nominal Thickness of Outer Sheath mm Nominal Overall Diameter mm Approx. Weight kg/km

1×2×0.75

0.8

1.2

1.25

12.9

200

3×2×0.75

0.8

1.2

1.4

17.9

468

7×2×0.75

0.8

1.4

1.7

22.4

706

12×2×0.75

0.8

1.6

1.7

28.0

1030

20×2×0.75

0.8

1.8

2.0

35.2

1662

1×3×0.75

0.8

1.0

1.25

13.5

285

3×3×0.75

0.8

1.3

1.2

20.4

680

7×3×0.75

0.8

1.5

1.4

26.0

1325

12×3×0.75

0.8

1.7

1.7

34.6

2106

1×2×1.0

0.8

1.0

1.0

13.4

180

1×3×1.0

0.8

1.1

1.1

14.0

300

1×4×1.0

0.8

1.1

1.2

15.0

180

1×2×1.5

0.8

1.1

1.2

13.5

297

3×2×1.5

0.8

1.3

1.4

19.8

593

7×2×1.5

0.8

1.4

1.6

25.0

929

12×2×1.5

0.8

1.7

1.9

32.6

1510

20×2×1.5

0.8

1.9

2.1

39.9

2287

1×3×1.5

0.8

1.1

1.2

14.0

304

3×3×1.5

0.8

1.3

1.5

23.7

760

7×3×1.5

0.8

1.5

1.7

30.5

1262

12×3×1.5

0.8

1.8

2.0

40.7

2148

1×2×2.5

0.8

1.1

1.2

15.1

320