HOMEPRODUCTS MARINE CABLES

 

UKOOA TYPE GL / TYPE GN 150/250V Fire Resistant

 

Application:

Marine cables are designed for fixed installation for control and lighting in both and safe areas, emergency and critical offshore applications where cable protection is required.

Standards:

BS 6883/BS 7917/UKOOA

IEC 60331-21

IEC 60332-3-22 CAT. A

IEC 60332-1

IEC 60754-1 & IEC 60754-2

IEC 61034-1 & IEC 61034-2

Construction:

Conductors:Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS 6360/IEC 60228.

Fire Protection:Mica glass tape

Insulation:EPR complying with BS7655 GP4 

Drain Wire:Tinned copper drain wire 

Collective Screen:Aluminium mylar tape screen

Bedding:EVA - SW4 compound complying with BS 7655 

Armour :Galvanised steel wire braid to BS 6883 

Outer Sheath :EVA - SW4 compound complying with BS 7655 (TYPE GL: Blue; TYPE GN: Grey) 

Dimensions and Weight:

Construction
No. of cores×Cross section
Nominal Insulation Thickness
Nominal Thickness of Inner Sheath 
Nominal Thickness of Outer Sheath 
Nominal Overall Diameter
Approx. Weight
mm² mm mm mm mm kg/km
3×2×0.75 0.8 1.2 1.4 17.8 520
7×2×0.75 0.8 1.4 1.5 22.0 780
12×2×0.75 0.8 1.6 1.7 27.6 1150
20×2×0.75 0.8 1.8 2.0 35.3 1900
3×3×0.75 0.8 1.3 1.5 20.0 520
7×3×0.75 0.8 1.5 1.7 25.3 870
12×3×0.75 0.8 1.8 2.0 33.6 1500
1×4×0.75 0.8 1.2 1.2 17.1 390
1×2×1.0 0.8 1.0 1.0 14.0 180
1×3×1.0 0.8 1.0 1.0 14.3 300
1×4×1.0 0.8 1.1 1.2 15.3 430
1×2×1.5 0.8 1.2 1.3 14.4 320
3×2×1.5 0.8 1.3 1.4 23.4 771
7×2×1.5 0.8 1.4 1.6 29.2 1189
12×2×1.5 0.8 1.7 1.9 37.3 1869
3×3×1.5 0.8 1.3 1.3 27.7 979
7×3×1.5 0.8 1.5 1.5 35.1 1594
12×3×1.5 0.8 1.8 1.8 46.3 2647
1×4×1.5 0.8 1.2 1.4 19.2 600