HOMEPRODUCTS MARINE CABLESBS 6883/BS 7917 OFFSHORE & MARINE CABLES

 

 

BS 6883/BS7917 Offshore & Marine cables

HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Non Radial Field)

 


Application:

HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards:

BS 6883

IEC 60332-3A Flame retardant

IEC 60754-1; IEC 60754- 2 Corrosivity

IEC 61034-2 Smoke density

Cold bend and impact (-40°C) (on request)

CSA C22.2 No. 38-95 (on request)

Construction:

HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables

Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.

Conductor Screen: Semiconducting layer or tape.

Insulation: HF-EPR GP5 according to BS 7655 1.2.

Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Armour: Galvanized steel wire braid or tinned bronze wire braid (single core).

Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties:

Minimum Internal Bending Radius: 12×OD

Temperature Range: -40℃ ~ +90℃

Dimensions and Weight:

3.8/6.6kV

Construction
No. of cores×Cross section
mm²
Nominal Insulation Thickness
mm
Nominal Inner Sheath Thickness
mm
Minimum Diameter Over Inner Sheath
mm
Maximum Diameter Over Inner Sheath
mm
Nominal Armour Wire Diameter
mm
Nominal Outer Sheath Thickness
mm
Minimum Overall Diameter
mm
Maximum Overall Diameter
mm
Approx. Weight
kg/km
1×16 3.4 1.3 13.9 15.7 0.3 1.4 18.0 20.4 703
1×25 3.4 1.3 15.5 17.5 0.3 1.5 19.8 22.7 899
1×35 3.4 1.4 16.6 18.6 0.3 1.5 20.9 23.8 1029
1×50 3.4 1.4 17.8 19.8 0.3 1.6 22.3 25.2 1223
1×70 3.4 1.5 19.7 22.1 0.3 1.7 24.4 27.4 1547
1×95 3.4 1.6 21.6 24.1 0.3 1.8 26.5 29.6 1903
1×120 3.4 1.6 23.2 25.8 0.3 1.8 28.1 31.3 2266
1×150 3.4 1.7 24.9 27.6 0.45 1.9 30.7 34.4 2760
1×185 3.4 1.8 26.9 29.6 0.45 2.0 32.9 36.7 3282
1×240 3.4 1.9 29.6 32.8 0.45 2.1 35.8 39.7 4059
1×300 3.4 2.0 32.1 35.4 0.45 2.2 38.5 42.9 4872
1×400 3.4 2.1 35.5 38.9 0.45 2.4 42.2 46.8 5844
1×500 3.4 2.2 38.7 42.6 0.45 2.5 45.7 50.4 7113
1×630 3.4 2.4 42.6 46.6 0.45 2.7 49.9 55.2 9093
3×16 3.4 1.8 28.1 30.9 0.45 2.1 34.3 38.2 2109
3×25 3.4 2.0 31.9 35.2 0.45 2.2 38.3 42.3 2747
3×35 3.4 2.0 33.8 37.1 0.45 2.3 40.4 44.9 3133
3×50 3.4 2.2 36.8 40.2 0.45 2.4 43.5 48.2 3772
3×70 3.4 2.3 40.7 44.6 0.45 2.6 47.9 52.7 4771
3×95 3.4 2.5 44.7 48.8 0.45 2.8 52.3 57.7 5900
3×120 3.4 2.6 48.6 53.1 0.45 2.9 56.3 61.8 7098
3×150 3.4 2.7 51.9 56.6 0.45 3.1 60.1 66.2 8304
3×185 3.4 2.9 56.2 61.1 0.45 3.2 64.6 70.8 9895
3×240 3.4 3.1 62.0 67.4 0.45 3.5 70.9 77.9 12358

6.6/6.6kV

Construction
No. of cores×Cross section mm²
Nominal Insulation Thickness
mm
Nominal Inner Sheath Thickness
mm
Minimum Diameter Over Inner Sheath
mm
Maximum Diameter Over Inner Sheath
mm
Nominal Armour Wire Diameter
mm
Nominal Outer Sheath Thickness
mm
Minimum Overall Diameter
mm
Maximum Overall Diameter
mm
Approx. Weight
kg/km
1×25 5.5 1.5 19.9 22.4 0.3 1.7 24.6 27.7 1211
1×35 5.5 1.5 20.8 23.3 0.3 1.7 25.5 28.6 1338
1×50 5.5 1.6 22.2 24.7 0.3 1.8 27.1 30.2 1565
1×70 5.5 1.7 24.1 26.7 0.45 1.9 29.9 33.6 2017
1×95 5.5 1.7 25.8 28.5 0.45 2.0 31.8 35.5 2383
1×120 5.5 1.8 27.7 30.4 0.45 2.0 33.7 37.5 2794
1×150 5.5 1.9 29.3 32.5 0.45 2.1 35.5 39.4 3213
1×185 5.5 1.9 31.1 34.3 0.45 2.2 37.5 41.5 3737
1×240 5.5 2.0 33.8 37.2 0.45 2.3 40.4 44.9 4548
1×300 5.5 2.1 36.4 39.8 0.45 2.4 43.1 47.7 5392
1×400 5.5 2.3 39.9 43.8 0.45 2.6 47.0 51.8 6384
1×500 5.5 2.4 43.2 47.2 0.45 2.7 50.5 55.8 7689
1×630 5.5 2.5 46.8 51.0 0.45 2.8 54.3 59.8 9709
3×25 5.5 2.3 41.2 45.1 0.45 2.6 48.4 53.6 3746
3×35 5.5 2.4 43.3 47.3 0.45 2.7 50.6 55.9 4204
3×50 5.5 2.5 46.1 50.2 0.45 2.8 53.6 59.0 4872
3×70 5.5 2.7 50.2 54.8 0.45 3.0 58.1 64.1 5992
3×95 5.5 2.8 54.0 58.8 0.45 3.1 62.1 68.3 7130
3×120 5.5 3.0 58.0 63.0 0.45 3.3 66.5 72.9 8486
3×150 5.5 3.1 61.4 66.8 0.45 3.4 70.1 77.0 9723
3×185 5.5 3.3 65.7 71.3 0.45 3.6 74.8 81.9 11448
3×240 5.5 3.5 71.5 77.6 0.45 3.9 81.2 89.0 14038

6.35/11kV

Construction
No. of cores×Cross section mm²
Nominal Insulation Thickness
mm
Nominal Inner Sheath Thickness
mm
Minimum  Diameter Over Inner Sheath
mm
Maximum Diameter Over Inner Sheath
mm
Nominal Armour Wire Diameter
mm
Nominal Outer Sheath Thickness
mm
Minimum Overall Diameter
mm
Maximum Overall Diameter
mm
Approx. Weight
kg/km
1×35 6.5 1.6 22.9 25.5 0.3 1.8 27.8 31.0 1514
1×50 6.5 1.7 24.3 26.9 0.45 1.9 30.1 33.8 1751
1×70 6.5 1.7 26.0 28.7 0.45 2.0 32.0 35.8 2201
1×95 6.5 1.8 27.9 30.7 0.45 2.1 34.1 37.9 2600
1×120 6.5 1.9 29.8 32.9 0.45 2.1 36.0 39.9 3021
1×150 6.5 1.9 31.2 34.5 0.45 2.2 37.6 41.6 3427
1×185 6.5 2.0 33.3 36.5 0.45 2.3 39.8 44.3 3987
1×240 6.5 2.1 36.0 39.4 0.45 2.4 42.7 47.3 4814
1×300 6.5 2.2 38.5 42.3 0.45 2.5 45.4 50.1 5674
1×400 6.5 2.4 42.0 46.0 0.45 2.6 49.2 54.4 6637
1×500 6.5 2.5 45.3 49.4 0.45 2.8 52.8 58.2 7986
1×630 6.5 2.6 48.9 53.5 0.45 2.9 56.6 62.2 10057
3×35 6.5 2.6 47.8 52.0 0.45 2.9 55.5 61.1 4793
3×50 6.5 2.7 50.6 55.2 0.45 3.0 58.5 64.6 5489
3×70 6.5 2.8 54.5 59.3 0.45 3.2 62.8 69.0 6612
3×95 6.5 3.0 58.6 63.5 0.45 3.3 67.0 73.4 7829
3×120 6.5 3.1 62.4 67.8 0.45 3.5 71.3 78.2 9182
3×150 6.5 3.3 66.0 71.5 0.45 3.6 75.0 82.2 10498
3×185 6.5 3.4 70.1 76.1 0.45 3.8 79.5 87.2 12218